Installing the replacement hard drive
Prerequisites
Verify that you are observing all ESD safety precautions before unwrapping the new hard drive.
1. Lift the release lever and insert the new hard drive into the bay until the locking tab
engages.
2. Close the release lever to securely seat the hard drive in the bay.
3. Monitor the RAID rebuild of the new hard drive.
• For an MSS, on the
Messaging Administration
menu, under
Server
Information
, select
Rebuild RAID Status
. The RAID Rebuild Status page
shows the percent complete of the disk drive recovery.
• For an MAS, information event 1216 displays in the Windows Event Viewer
System Event Log when the failed drive is replaced. The MAS major alarm
is resolved, and a minor alarm is raised. When the RAID rebuild is
complete, information event 1200 displays in the Windows Event Viewer
System Event Log. The event description should give a status of
2
indicating that the drive is OK. The MAS minor alarm is resolved when event
1200 displays.
4. Verify that the hard drive failure alarm has resolved. For more information about
displaying active and resolved alarms, see the maintenance section of
Avaya
Modular Messaging Help
.
Adding and replacing a hard drive
44 Maintaining the Avaya S8730 Server for Modular Messaging
June 2009
Summary of Contents for S8730
Page 1: ...Maintaining the Avaya S8730 Server for Modular Messaging Issue 1 June 2009...
Page 10: ...Safety Information 10 Maintaining the Avaya S8730 Server for Modular Messaging June 2009...
Page 12: ...Site preparation 12 Maintaining the Avaya S8730 Server for Modular Messaging June 2009...
Page 40: ...Replacing a DVD drive 40 Maintaining the Avaya S8730 Server for Modular Messaging June 2009...
Page 48: ...Replacing a fan 48 Maintaining the Avaya S8730 Server for Modular Messaging June 2009...