Chapter 2 Avaya P330-ML Layer 2 CLI Commands
Avaya
P330-ML Reference Guide
205
The syntax for this command is:
snmp-server
informs retries
<retries-num>
timeout
<seconds>
Example:
snmp-server remote-user
User level: supervisor
Use the
snmp-server remote user
command to configure a remote-user as a
target for SNMP notifications.
The syntax for this command is:
snmp-server remote-user
<username> <engineID> <groupname>
{
v1
|
v2c
|
v3
} [
auth
{
md5
|
sha
} <auth-password>
[
priv des56
<priv-password>]]
retries-num
Maximum number of times to resend an inform request.
seconds
Number of seconds to wait for an acknowledgment before
resending. The default is 3.
P330-N>
snmp-server informs retries 5 timeout 30
Done!
username
Variable that specifies the name of the SNMP user. The
maximum length is 32 bytes.
engineID
The remote SNMP engineID. The SNMP engineID is a 12 byte
string represented as hexadecimal numbers separated by the
colon character.
For example, 00:00:00:81:0a:fe:ff:12:97:33:45:12.
groupname
Variable that specifies the name of the SNMP group. The
maximum length is 32 bytes.
v1
,
v2c
,
v3
The security model assigned to the user in user to group
association.
auth
(Optional)
A keyword signifying that an authentication password is
required.
md5
,
sha
Keyword that specifies authentication protocol, either
HMAC-SHA-96 or MAC-MD5-96.
priv-
password
The privacy password. Valid lengths are 8 - 64 characters.
Summary of Contents for P330-ML-ML
Page 1: ...Avaya Reference Guide AVAYA P330 ML ML STACKABLE SWITCH SOFTWARE VERSION 4 5 January 2004 ...
Page 2: ......
Page 22: ...Chapter 1 Using the CLI 8 Avaya P330 ML Reference Guide ...
Page 161: ...Chapter 2 Avaya P330 ML Layer 2 CLI Commands Avaya P330 ML Reference Guide 147 Example ...
Page 226: ...Chapter 2 Avaya P330 ML Layer 2 CLI Commands 212 Avaya P330 ML Reference Guide ...
Page 320: ...Index of Layer 3 CLI Commands 304 Avaya P330 ML Reference Guide ...