![Avaya G600 Installing Manual Download Page 193](http://html1.mh-extra.com/html/avaya/g600/g600_installing-manual_3027010193.webp)
193
Installing the Avaya™ S8700 Media Server with Avaya™ MCC1 or SCC1 Media Gateway
Installing and Wiring Telephones
May 2003
808A Emergency Transfer Panel Mounting
Install the 808A Emergency Transfer panel
NOTE:
The 808A must be installed in a location that can be accessed only by authorized
personnel. The location must meet standard environmental considerations such as
temperature, humidity, and so forth.
1
Verify dial tone is present at each trunk circuit.
2
Locate the circuit start selection switches (see
‘‘808A Emergency Transfer Panel’’ on
).
These are the first 10 two-position switches on the left side of the Emergency Transfer
Panel. They are used to set each of the five incoming trunk lines to either loop start or
ground start. Two switches are used for each circuit; switches 1 and 2 are used for circuit
1, switches 3 and 4 are used for circuit 2, and so forth. See
.
3
For loop start, set the switches to the left. For ground start, set the switches to the right.
4
Connect a 25-pair cable between the male RJ21 25-pair connector on the Emergency
Transfer Panel and the yellow field of the Main Distribution Frame (MDF).
Assignments for 25-Pair Connector’’ on page 195
shows the pinouts.
Figure notes
1
808A Emergency Transfer Panel
2
Ear for Screw Mount
3
Cut-Out for Snap Mount
4
25-Pair Male Connector
5
Circuit Start Switches
808a_em LJK 042396