![Avaya G600 Installing Manual Download Page 129](http://html1.mh-extra.com/html/avaya/g600/g600_installing-manual_3027010129.webp)
129
Installing the Avaya™ S8700 Media Server with Avaya™ MCC1 or SCC1 Media Gateway
Connect the MDF to Stations and PSTN
May 2003
4-Pair Run to Equipment Room or Satellite Location
4-Pair Run to Equipment Room or Satellite Location
Figure notes
1
Station Side of MDF or Satellite
Location
2
4-Pair Circuit
3
Blue Field
4
DIW Station Cable (D-Inside
Wire)
5
Information Outlet
Figure notes
1
Part of MDF
2
3-Pair Connecting Blocks
3
4-Pair Connecting Blocks
4
Purple Field
5
Patch Cord or Cross-Connect
Jumpers
6
Blue Field
7
To Media Gateway (3-pair
modularity)
8
A25D Cable
9
258A or BR2580A Adapter
10
Information Outlet
11
4-Pair Circuit (DIW station cable
(D-Inside Wire))
3
4
1
5
2
2
r764798a CJL 030796
8
7
1
9
10
11
r758532a CJL 031196
2
4
3
6
5