Installing the Avaya™ S8700 Media Server with Avaya™ MCC1 or SCC1 Media Gateway
Connect the MDF to Stations and PSTN
May 2003
Three-pair circuits can also be run directly from the equipment room MDF to a 356A adapter as
shown in
‘‘3-Pair to 4-Pair Circuit Distribution and Connectivity’’ on page 131
. Four-pair
station cables connect the adapter to the information outlets. Four-pair station cables can be run
directly from a satellite location to the information outlets as previously described.
NOTE:
Bridged taps are not allowed on any part of the station wiring.
4-Pair Circuit Distribution and Connectivity