- 6 -
User Manual
Installation Steps
1.
Check to see if the ice machine is in good condition and the accessories are all present; check
the machine model and the machine nameplate.
2.
Clean the ice storage bin and the food area inside with a sponge soaked in warm water and
soap.
Then rinse with potable water and dry.
3.
Place the ice machine in the operation area; ensure that the machine is placed on a leveled
floor
so the water flows evenly into the evaporator.
4. The compressor chamber is located below the front of the ice bin where the compressor
and condenser are installed. It requires good ventilation so the ice maker must have ventilation
space of more than 8” in the rear, 6” on the sides, and 12” in the front.
5.
The bottom of the ice machine is equipped with adjustable legs for level adjustment and
clearance for floor cleaning.
6.
Connect the ice machine’s inlet water filter and water line referring to the installation
instructions
of your water filter brand. If the installation site is already equipped with a
drinking water system,
the water filter may not be
needed.
7.
Connect the machine to the water supply using the 3/4” inlet fitting supplied with the
machine. It is recommended to install a water ball valve (not supplied with this machine) on
the water supply line.
8.
Connect the drain line to the drain connector.
T
o achieve a proper draining, it is
recommended
that the drain pipe should have a difference in level of more than 1” per 3’; and
confirm that the
drain line is not blocked. It is recommended that the drain line be connected
to an open
drainage port.
9.
Any joint in the drain line must not be higher than the machine drainage port; any joint in the
drain line cannot be higher than the previous joint.
10.
Confirm the power requirements stated in the machine’s nameplate; ensure that the power
supply meets the requirements.
11.
A circuit breaker or switch with leakage protector and reliable grounding is required.
12.
Turn off the switch on the power line and connect the machine to the power source.
NOTE: the filter flow direction should be correctly installed as per the direction marker on
the filter head cover or the filter body. The filter cartridge should be replaced every
3 to 6 months.