![Avalon La Petite-X Service Manual Download Page 57](http://html1.mh-extra.com/html/avalon/la-petite-x/la-petite-x_service-manual_3024294057.webp)
The Petite-X Revision B 03/2010
SERVICE MANUAL AVALON
La Petite-X
Single-Cup Brewer
57
Preventive Maintenance
9.3
Water Outlet Valves
Quarterly or as needed
To avoid any problems related to mineral deposits over time, we recommend to inspect the 3 valves.
Leaking valve
a. Identify the leaking valve and replace it
b. If the leak comes from under the body of the valve or from the tank exit, try simply changing the
conical mounting seal.
Removing and installing the valves
1. Turn off the machine;
2. Unplug the lid (fig.1.1) and the valves (fig. 1.2);
3. Drain the water from the water tank completely (see p.56);
4. Remove the tubes;
5. Unscrew the tank guard to remove the tank;
6. Tilt the tank towards you to have access to the valves;
7. Remove the valve;
8. Reinstall by repeating in the reverse order
If you choose to install a water filtration system, it is recommended that the filter be checked on a
monthly basis.
Caution water is hot!
Tank guard
Valves
Double valve
Simple valve
Tank Lid Fig. 1.1
Valves Fig. 1.2
Disconnect
these connectors