The  power  and  control  (CL)  wires 
must be permanently connected 

6. WIRING 

 

The YD25 is fitted with eight connectors; five are optional and provide monitoring of the lock pin and door positions. 
Control  of  the  lock  is  achieved  by  using  the  remaining  three  wires  however  a  reduced  function  two  wire  mode  is 
available if desired. Connect the YD25 as per the following chart. 
 
 

+

 

Power 

Positive connection to DC power supply (12 

– 24V) 

CL 

Switched positive control input  

Negative connection to DC power supply (12 

– 24V) 

Door Position Switch  

Common contact of the door position monitor  

NO 

Normally open contact of the door position monitor 

Bolt Position Switch 

Common contact of the bolt position monitor 

NO 

Normally open contact of the bolt position monitor 

NC 

Normally closed contact of the bolt position monitor 

 
 

6.1. Three wire connection 

 

 

The  three  wire  mode  requires  a  continuous                                                                                                                      
connection of power to terminals 1 (+ve) and 3 (-ve). 
Wiring the lock for fail safe or fail secure configurations 
is identical. 
 
 

 
 

6.2. Two wire connection 

 

The two wire mode differs between fail safe and fail secure configurations but both require a switched power supply 
connected to terminals ‘1’ and ‘3’. In addition, for fail safe configuration the dip switch needs to be repositioned as 
shown in 

Section 6.4 - Dip switch positions. 

Wire links 

(not supplied)

 are connected from termin

als ‘2’ to ‘4’ and ‘1’ 

to ‘5’ for fail safe. A wire link is connected between terminals ‘1’ and ‘2’ for fail secure. 
 
 
 

 
 
 

 
 
 
 
 
 

 

        Fail Safe 

 

 

 

 

 

              Fail Secure  

 

6.3. Monitors 

 
The five monitor connectors found on the YD25 are available to provide door and bolt position feedback. If desired 
wires can be run from these connections to integrate with access control or alarm systems to provide full monitoring. 
When a two wire fail safe operation is chosen the door position monitor is not available. 

 

 

The  bolt  position  switch  is 
an optional connection 

Switched  power  supply 
permanently connected 

The monitor switches are optional connections 

The monitor switches are optional connections 

Switched  power  supply 
permanently connected 

Summary of Contents for BQT YD25

Page 1: ...INSTALLATION AND OPERATING INSTRUCTIONS Solenoid Dropbolt YD25 ...

Page 2: ...product is carrying the CE Mark in accordance with the related European Directives Responsible for CE Marking is BQT Solutions SEA Pte Limited 41B Neil Road 03 01 Singapore 088824 The complete EU Declaration of Conformity is available at www bqtsolutions com In the European Union Norway Iceland and Liechtenstein This symbol on the product or in the manual and in the warranty and or on its packagin...

Page 3: ...STALLATION ASSESSMENT 5 4 1 MECHANICAL 5 4 2 ELECTRICAL 6 5 INSTALLATION 6 5 1 MORTISE INSTALLATION 6 5 2 SURFACE INSTALLATION 8 6 WIRING 10 6 1 THREE WIRE CONNECTION 10 6 2 TWO WIRE CONNECTION 10 6 3 MONITORS 10 6 4 DIP SWITCH POSITIONS 11 7 OPERATION 11 7 1 THREE WIRE MODE RECOMMENDED 11 7 2 TWO WIRE MODE 11 8 SPECIFICATIONS 12 9 MAINTENANCE AND INSPECTION 12 ...

Page 4: ...ures Multi voltage input 12 24VDC Multiple locking unlocking attempts Adjustable timed re lock Current reduction circuitry Door position and bolt position monitors High physical strength 10 000N 2 PRODUCT UNBOXED The YD25 is supplied with four 10G x 1 csk self tapping screws for fitting the lock and strike plate They are suitable for mounting in both aluminium and wooden doors and frames Also incl...

Page 5: ... first decision regarding installation is whether the YD25 will be mortised or surface mounted to the door door frame Mortise installation ensures a discrete solution as the lock and strike plate can be embedded into the door and frame however in some instances this is not possible Glass doors for example require surface mounting the lock which is done with the aid of the YD25 housing ...

Page 6: ...onnections to integrate into access control or alarm systems to provide full monitoring Finally the correct gauge of wire needs to be chosen as when connecting the power wires and to the lock voltage drop across these wires can limit the lock operation For all the remaining connections a lower gauge wire can be used as these are only signal wires The following chart shows the appropriate wire gaug...

Page 7: ...d deep enough to allow the lock pin to fully extend when locked 5 1 2 Wiring the lock Wires are run out from the back of the mortise and following the connection guide on the locks cover connected to the lock Detailed wiring information can be found in Section 6 Wiring 5 1 3 Fitting the lock and strike plate The lock is slid back into the mortise making sure that the wiring integrity is maintained...

Page 8: ... 10G x 1 hex head self tapping screws are supplied with the housing and can be screwed into the wood door frame The housing has two keyhole cut outs that fit over the screw heads and once the housing is in place the screws can be tightened with a spanner 5 2 2 Wiring the lock The wires will need to be run into the housing to connect to the lock The position of the hole is determined at installatio...

Page 9: ...5 housings are supplied with self adhesive tape With the backing removed the housing can be applied directly to the glass A flat stainless steel dress plate is fitted on the opposite of the glass to give a clean finish 5 2 5 Fitting the strike plate The strike plate is placed into the housing and secured in place with the M5 x 10 csk screws that were supplied with the lock 5 2 6 Checking the opera...

Page 10: ...1 ve and 3 ve Wiring the lock for fail safe or fail secure configurations is identical 6 2 Two wire connection The two wire mode differs between fail safe and fail secure configurations but both require a switched power supply connected to terminals 1 and 3 In addition for fail safe configuration the dip switch needs to be repositioned as shown in Section 6 4 Dip switch positions Wire links not su...

Page 11: ...stay unlocked indefinitely 7 1 1 Fail safe operation Assume the door is closed and locked Momentarily connecting 1 and 2 unlocks the door for a period of 9 seconds After the 9 seconds has elapsed if the door has not been opened the YD25 automatically locks again If the door has opened within the 9 second window which is the case in normal operation the timed re lock is overridden and automatic rel...

Page 12: ...ons A dry cloth can be used to polish the stainless steel face plate and strike plate as required This lock contains components that are subject to wear based on usage doorway operation and installation all such factors are beyond the control and measurement of the manufacturer The lock may be vulnerable and subject to failure as a consequence of wear and as its components near the end of the peri...

Reviews: