Page 9
5.2.3. Fitting the lock
Once wired, the lock is slid into the housing and
secured in place with the M5 X 10 csk screws
that were supplied with the lock. Make sure that
the wiring integrity is maintained as the lock is
screwed in place.
5.2.4. Securing the housing to glass
For simple application to glass the YD25
housings are supplied with self-adhesive tape.
With the backing removed the housing can be
applied directly to the glass. A flat stainless steel
dress plate is fitted on the opposite of the glass
to give a clean finish.
5.2.5. Fitting the strike plate
The strike plate is placed into the housing and
secured in place with the M5 x 10 csk screws
that were supplied with the lock.
5.2.6. Checking the operation
With the lock and strike installed and the wiring
complete the door is closed to check alignment
and operation.