78
•
The Menu Items
Cue-Out
Menu "Cue-Out" is used for selecting the signal to be output at
CUE-OUT. When programming with Wings Platinum, this is
usually DLC. While playing back the show, the type of signal
used depends on the "Priority" setting; otherwise the menu
setting applies.
Note:
Menus
DigiLft
and
DigiRgt
are without function.
ExtTC (External Timecode)
Two submenus allow settings for evaluation of incoming
timecode to be made.
Stop0TC
In this menu you specify the actions to be taken when time-
code fails. With a setting of ST=OFF the show is continued
without incoming timecode. With a setting of ST=ON the show
is put into Pause Mode when the timecode fails. When the
timecode signal is applied again the show is continued at the
corresponding location. Please bear in mind that extensive
leaps in time may cause status problems for complex shows
using a number of peripheral devices.
DropOut
This menu allows entry of a time between 0.1 and 2.5 seconds
and is the period a show is to be continued after incoming
timecode has failed. The default setting is DO=100, which
Summary of Contents for SC MASTER LITE