SC MASTER LITE
The Menu Items
•
67
address for a master unit is always NA=1; NA=0 disables SC
Net operation.
ExtAdrs (External SCNet Addresses)
This menu is used for allocating addresses to SCNet modules.
The SCNet Module is set to Config Mode and configured by
selecting the corresponding address (EA=2....125). Further
information can be found in the SCNet Module operating
instructions.
SCNBaud (SC Net Baud rate)
This menu allows you to influ-
ence the speed of communication within the SC Net. The
default setting is "Auto Baud" (AudoBd). This means that the
SC MASTER automatically negotiates the baud rate for com-
munication with the SC Net modules. For networks with a
large number of modules or long cable connections it will be
safer to set the baud rate manually. Choose a baud rate which
ensures that even the last SC Net Module is still able to com-
municate. If no communication can be established although
the cable connection is correct, the baud rate setting is too
high.
ContShw (Continue Show)
Here you can deactivate function "Continue Show" (CS=OFF).
This may be useful for permanent installations which are to be
activated or deactivated centrally. Further information can be
found in chapter
Continuing a show after power failure
on
page 47.