AUX DC Inverter Free Match 50HZ
R32
59
System Format
1 drive 2
1 drive 2
Capacity
Cooling
Btu/h
13989(6142-15388)
18084(6824-19892)
kW
4.1(1.8-4.51)
5.3(2.0-5.83)
Heating
Btu/h
16378(6995-18015)
19107(7541-21017)
kW
4.8(2.05-5.28)
5.6(2.21-6.16)
Electric Data
Power Supply
V~,Hz,Ph
220~240,50,1
220~240,50,1
Cooling Power Input
W
1240(198-2100)
1750(280-2300)
Heating Power Input W
1150(198-2100)
1540(280-2300)
Rated Current
(cooling&heating)
A
5.4/5
7.6/6.7
Max current
A
10
11
Max power
KW
2.1
2.3
Performance
SEER/SCOP
W/W
6.16/4.06
(
F
)
7.07/4.08
(
F
)
SEER/SCOP
W/W
6.15/4.05
(
L
)
7.08/4.06
(
L
)
SEER/SCOP
W/W
6.16/4.06(J)
7.07/4.07(J)
Energy Rate
A++/A+
A++/A+
EER/COP
W/W
3.31/4.17
3.03/3.64
DC Inv.
Compressor
Model
KSN108D22UFZ
KSM135D23UFZ
Quantity
1
1
Type
Rotary
Rotary
Brand
GMCC
GMCC
Capacity
W
3470
4245
Input
W
890
1075
Power Supply
V~,Hz,Ph
220~240,50,1
220~240,50,1
Rated Current
A
6.05
7.1
Operating Frequency Hz
60
60
Frequency Range
VG74/310ml
VG74/440ml
Refrigerant Oil
ml
10~120Hz
10~120Hz
Outdoor DC
Model
D-40-8
D-40-8
Summary of Contents for F Series
Page 1: ...1 Technical Manual DC Inverter Free Match R32 ...
Page 2: ...2 2019 07 ...
Page 7: ...7 Part1 General Information 1 Nomenclature Indoor Unit Outdoor Unit ...
Page 9: ...9 24K Btu h AMWM H24 4R3 J ...
Page 27: ...AUX DC Inverter Free Match 50HZ R32 27 ...
Page 30: ...AUX DC Inverter Free Match 50HZ R32 30 Part3 Piping System 1 14K 18K ...
Page 33: ...AUX DC Inverter Free Match 50HZ R32 33 3 36K ...
Page 70: ...AUX DC Inverter Free Match 50HZ R32 70 ...
Page 71: ...AUX DC Inverter Free Match 50HZ R32 71 3 Ceiling Floor 09K 12K 18K 929 660 245 841 205 ...
Page 74: ...AUX DC Inverter Free Match 50HZ R32 74 5 Outdoor Unit 5 1 14K 18K 545 800 545 822 315 315 ...
Page 75: ...AUX DC Inverter Free Match 50HZ R32 75 5 2 21K 27K 834 540 655 854 335 328 ...
Page 76: ...AUX DC Inverter Free Match 50HZ R32 76 5 3 36K 42K 985 675 808 1000 409 395 ...
Page 80: ...AUX DC Inverter Free Match 50HZ R32 80 ...
Page 82: ...AUX DC Inverter Free Match 50HZ R32 82 3 Ceiling Floor 09k 12k 18k ...
Page 83: ...AUX DC Inverter Free Match 50HZ R32 83 4 Duct 07K 09K 12K 18K ...
Page 92: ...AUX DC Inverter Free Match 50HZ R32 92 Part8 Static pressure curve 1 07K 09K Duct ...
Page 93: ...AUX DC Inverter Free Match 50HZ R32 93 2 12K Duct ...
Page 94: ...AUX DC Inverter Free Match 50HZ R32 94 3 18K Duct ...
Page 103: ...AUX DC Inverter Free Match 50HZ R32 103 XK 04 Detailed operation instructions 6 ...
Page 158: ...AUX DC Inverter Free Match 50HZ R32 158 2 Cassette 09K 12K 18K ...
Page 164: ...AUX DC Inverter Free Match 50HZ R32 164 ...
Page 166: ...AUX DC Inverter Free Match 50HZ R32 166 4 2 18K ...
Page 168: ...AUX DC Inverter Free Match 50HZ R32 168 5 Outdoor Unit 5 1 14K 18K ...
Page 170: ...AUX DC Inverter Free Match 50HZ R32 170 5 2 21K 27K ...
Page 171: ...AUX DC Inverter Free Match 50HZ R32 171 ...
Page 173: ...AUX DC Inverter Free Match 50HZ R32 173 5 3 36K ...
Page 176: ...AUX DC Inverter Free Match 50HZ R32 176 5 4 42K ...
Page 183: ...AUX DC Inverter Free Match 50HZ R32 183 4 Cassette 4 1 Installation drawing ...
Page 184: ...AUX DC Inverter Free Match 50HZ R32 184 4 2 The distance between indoor unit and obstacle ...
Page 189: ...AUX DC Inverter Free Match 50HZ R32 189 ...
Page 196: ...AUX DC Inverter Free Match 50HZ R32 196 ...
Page 211: ...AUX DC Inverter Free Match 50HZ R32 211 1 2 21K 27K Main PCB and Driver modular ...
Page 212: ...AUX DC Inverter Free Match 50HZ R32 212 1 3 36K 42K Main PCB ...
Page 213: ...AUX DC Inverter Free Match 50HZ R32 213 Drive Modular Board ...
Page 214: ...AUX DC Inverter Free Match 50HZ R32 214 2 Indoor Unit PCB 2 1 09K 12K 18K Cassette ...
Page 215: ...AUX DC Inverter Free Match 50HZ R32 215 2 2 09K 12K 18K Ceilling Floor ...
Page 216: ...AUX DC Inverter Free Match 50HZ R32 216 2 3 07k 09K 12K 18K Duct ...
Page 220: ...AUX DC Inverter Free Match 50HZ R32 220 ...
Page 222: ...AUX DC Inverter Free Match 50HZ R32 222 Outdoor protection phase sequence ...
Page 224: ...AUX DC Inverter Free Match 50HZ R32 224 Heating high pressure protection ...
Page 225: ...AUX DC Inverter Free Match 50HZ R32 225 2 4 H6 low pressure protection ...
Page 226: ...AUX DC Inverter Free Match 50HZ R32 226 Cooling low pressure protection ...
Page 227: ...AUX DC Inverter Free Match 50HZ R32 227 Heating low pressure protection ...
Page 228: ...AUX DC Inverter Free Match 50HZ R32 228 ...
Page 230: ...AUX DC Inverter Free Match 50HZ R32 230 Heating exhaust temperature protection ...
Page 231: ...AUX DC Inverter Free Match 50HZ R32 231 ...
Page 232: ...AUX DC Inverter Free Match 50HZ R32 232 2 6 H8 four way valve failure protection ...
Page 233: ...AUX DC Inverter Free Match 50HZ R32 233 ...
Page 234: ...AUX DC Inverter Free Match 50HZ R32 234 2 7 Sensor failure protection ...