AUX DC Inverter Free Match 50HZ
R32
156
No.
Chinese Name
Part Name
Part Code
Qty
1
面板
Panel
11320003002880
1
2
显示灯板
Display board
11222014000608
1
3
导风门
Air louver
(
Horizontal
)
11320005000360
1
4
过滤网
Filter
11220508000145
2
5
螺钉盖
Screw cover
11320096000102
3
6
中框接线盖
Medium frame wiring cover
11320076000105
1
7
中框装饰板
Medium frame decorating plate
11320088000039
1
8
中框组件
Medium frame assembly
11220501000778
1
8.1
左端盖
Left panel
11320078000161
1
8.2
中框
Medium frame
11320002000293
1
8.3
右端盖
Right panel
11320078000162
1
9
蒸发器总成
Evaporator assembly
11224003000820
1
9.1
蒸发器左支架
Evaporator left side carriage
11320015000123
1
9.2
蒸发器部件
Evaporator assembly
11224009000214
1
9.2
蒸发器部件
Evaporator assembly
11224009000213
1
9.3
蒸发器护套
Evaporator protecting bush
11320101000018
1
10
轴承固定座
Bearing fixed chassis
11320062000026
1
11
轴承组合件
Bearing assembly
11220551000003
1
12
贯流风叶
Cross flow fan
11220513000059
1
13
底座组件
Chassis assembly
11220500000289
1
Summary of Contents for F Series
Page 1: ...1 Technical Manual DC Inverter Free Match R32 ...
Page 2: ...2 2019 07 ...
Page 7: ...7 Part1 General Information 1 Nomenclature Indoor Unit Outdoor Unit ...
Page 9: ...9 24K Btu h AMWM H24 4R3 J ...
Page 27: ...AUX DC Inverter Free Match 50HZ R32 27 ...
Page 30: ...AUX DC Inverter Free Match 50HZ R32 30 Part3 Piping System 1 14K 18K ...
Page 33: ...AUX DC Inverter Free Match 50HZ R32 33 3 36K ...
Page 70: ...AUX DC Inverter Free Match 50HZ R32 70 ...
Page 71: ...AUX DC Inverter Free Match 50HZ R32 71 3 Ceiling Floor 09K 12K 18K 929 660 245 841 205 ...
Page 74: ...AUX DC Inverter Free Match 50HZ R32 74 5 Outdoor Unit 5 1 14K 18K 545 800 545 822 315 315 ...
Page 75: ...AUX DC Inverter Free Match 50HZ R32 75 5 2 21K 27K 834 540 655 854 335 328 ...
Page 76: ...AUX DC Inverter Free Match 50HZ R32 76 5 3 36K 42K 985 675 808 1000 409 395 ...
Page 80: ...AUX DC Inverter Free Match 50HZ R32 80 ...
Page 82: ...AUX DC Inverter Free Match 50HZ R32 82 3 Ceiling Floor 09k 12k 18k ...
Page 83: ...AUX DC Inverter Free Match 50HZ R32 83 4 Duct 07K 09K 12K 18K ...
Page 92: ...AUX DC Inverter Free Match 50HZ R32 92 Part8 Static pressure curve 1 07K 09K Duct ...
Page 93: ...AUX DC Inverter Free Match 50HZ R32 93 2 12K Duct ...
Page 94: ...AUX DC Inverter Free Match 50HZ R32 94 3 18K Duct ...
Page 103: ...AUX DC Inverter Free Match 50HZ R32 103 XK 04 Detailed operation instructions 6 ...
Page 158: ...AUX DC Inverter Free Match 50HZ R32 158 2 Cassette 09K 12K 18K ...
Page 164: ...AUX DC Inverter Free Match 50HZ R32 164 ...
Page 166: ...AUX DC Inverter Free Match 50HZ R32 166 4 2 18K ...
Page 168: ...AUX DC Inverter Free Match 50HZ R32 168 5 Outdoor Unit 5 1 14K 18K ...
Page 170: ...AUX DC Inverter Free Match 50HZ R32 170 5 2 21K 27K ...
Page 171: ...AUX DC Inverter Free Match 50HZ R32 171 ...
Page 173: ...AUX DC Inverter Free Match 50HZ R32 173 5 3 36K ...
Page 176: ...AUX DC Inverter Free Match 50HZ R32 176 5 4 42K ...
Page 183: ...AUX DC Inverter Free Match 50HZ R32 183 4 Cassette 4 1 Installation drawing ...
Page 184: ...AUX DC Inverter Free Match 50HZ R32 184 4 2 The distance between indoor unit and obstacle ...
Page 189: ...AUX DC Inverter Free Match 50HZ R32 189 ...
Page 196: ...AUX DC Inverter Free Match 50HZ R32 196 ...
Page 211: ...AUX DC Inverter Free Match 50HZ R32 211 1 2 21K 27K Main PCB and Driver modular ...
Page 212: ...AUX DC Inverter Free Match 50HZ R32 212 1 3 36K 42K Main PCB ...
Page 213: ...AUX DC Inverter Free Match 50HZ R32 213 Drive Modular Board ...
Page 214: ...AUX DC Inverter Free Match 50HZ R32 214 2 Indoor Unit PCB 2 1 09K 12K 18K Cassette ...
Page 215: ...AUX DC Inverter Free Match 50HZ R32 215 2 2 09K 12K 18K Ceilling Floor ...
Page 216: ...AUX DC Inverter Free Match 50HZ R32 216 2 3 07k 09K 12K 18K Duct ...
Page 220: ...AUX DC Inverter Free Match 50HZ R32 220 ...
Page 222: ...AUX DC Inverter Free Match 50HZ R32 222 Outdoor protection phase sequence ...
Page 224: ...AUX DC Inverter Free Match 50HZ R32 224 Heating high pressure protection ...
Page 225: ...AUX DC Inverter Free Match 50HZ R32 225 2 4 H6 low pressure protection ...
Page 226: ...AUX DC Inverter Free Match 50HZ R32 226 Cooling low pressure protection ...
Page 227: ...AUX DC Inverter Free Match 50HZ R32 227 Heating low pressure protection ...
Page 228: ...AUX DC Inverter Free Match 50HZ R32 228 ...
Page 230: ...AUX DC Inverter Free Match 50HZ R32 230 Heating exhaust temperature protection ...
Page 231: ...AUX DC Inverter Free Match 50HZ R32 231 ...
Page 232: ...AUX DC Inverter Free Match 50HZ R32 232 2 6 H8 four way valve failure protection ...
Page 233: ...AUX DC Inverter Free Match 50HZ R32 233 ...
Page 234: ...AUX DC Inverter Free Match 50HZ R32 234 2 7 Sensor failure protection ...