R32
High Efficiency DC Inverter LCAC
63
*Press the
HEAT
button,you can directly enter cooling mode.
*
Note:
cooling only unit has no heating function.
6.“SWING”button (SWING←→and SWING↑↓)
Press this button to start up/down (left/right) swing function, press itagain,fix louver
position.
*Up/down (left/right) setting is only valid in this mode;it will not affect louver
Position in other modes.
*Up/down (left/right)swing has memory function, it can keep primary setting when turn
off then turn on or switch from other modes to primary mode.
7. “HEALTH” button
* Press this button; you can turn on or off the health function.
8. “SLEEP” button
* Press SLEEP button, the sleeping indicator light of indoor unit flashes on.
* The air-conditioner runs in sleeping mode for 10 hours and quiet sleep mode, recover
back to former mode.
* The unit will turn off automatically if the timing mode is running out of time.
* Note: press the MODE or ON/OFF button, the remote controller clears sleeping mode
away.
9. “iFEEL” button
* Press this button to set “iFEEL”function. The LCD shows the actual room temperature
when the function set and it shows the setting temperature when the function can celled.
* This function is invalid at Fan mode.
10.“DISPLAY” button
* In display mode, press button once, switch off “DISPLAY”, Press “DISPLAY” again,
LCD will show ambient & setting temperature after flashing 5s. It's convenient for users to
check ambient or setting temperature at any time in darkness.
11.“iCLEAN” button
* When remote controller is at the off state, press this button, the unit
runs“iCLEAN”function .
* The purpose of this function is to clean dust on evaporator and dry the inside water of
evaporator and to prevent the evaporator going moldy due to water deposition and boasting
strange smell.
* After setting “iCLEAN” function, press“iCLEAN”button or“ON/OFF”button to quit.
* The clean function will stop working after about 30 minutes running without any
Summary of Contents for ALCF-H18/NDR3HA
Page 4: ......
Page 13: ...R32 High Efficiency DC Inverter LCAC 9 Optimized Centrifugal Fan Removable Control Box ...
Page 44: ...R32 High Efficiency DC Inverter LCAC 4 Outdoor Unit 4 1 12K 18K 800 545 545 315 315 860 ...
Page 45: ...R32 High Efficiency DC Inverter LCAC 41 4 2 24K 700 900 630 350 350 950 ...
Page 46: ...R32 High Efficiency DC Inverter LCAC 4 3 30K 36K 42K 808 970 675 409 395 1044 ...
Page 47: ...R32 High Efficiency DC Inverter LCAC 43 4 4 48K 60K 364 1010 1325 940 625 370 ...
Page 54: ...R32 High Efficiency DC Inverter LCAC 4 2 48K 60K ...
Page 60: ...R32 High Efficiency DC Inverter LCAC Part8 Static pressure curve 1 18K Duct Hi SET Normal ...
Page 61: ...R32 High Efficiency DC Inverter LCAC 57 2 24K Duct Hi SET Normal ...
Page 62: ...R32 High Efficiency DC Inverter LCAC 2 30K Duct Hi SET Normal ...
Page 63: ...R32 High Efficiency DC Inverter LCAC 59 2 36K 42K Duct Hi SET Normal ...
Page 64: ...R32 High Efficiency DC Inverter LCAC 3 48K 60K Duct Normal ...
Page 96: ...R32 High Efficiency DC Inverter LCAC Cassette and ceiling floor ...
Page 106: ...R32 High Efficiency DC Inverter LCAC 18 围板 A Baffle A 16421010000071 1 ...
Page 123: ...R32 High Efficiency DC Inverter LCAC 119 4 Outdoor Unit 4 1 12K 18K ...
Page 158: ...R32 High Efficiency DC Inverter LCAC 1 2 30K 36K 42K Main PCB Drive Modular Board ...
Page 159: ...R32 High Efficiency DC Inverter LCAC 155 1 3 48K 60K Main PCB Drive Modular Board ...
Page 161: ...R32 High Efficiency DC Inverter LCAC 157 Driver Modular ...
Page 165: ...R32 High Efficiency DC Inverter LCAC 161 Outdoor protection phase sequence ...
Page 168: ...R32 High Efficiency DC Inverter LCAC 2 4 2Heating low pressure protection ...
Page 169: ...R32 High Efficiency DC Inverter LCAC 165 ...
Page 171: ...R32 High Efficiency DC Inverter LCAC 167 Heating exhaust temperature protection ...
Page 172: ...R32 High Efficiency DC Inverter LCAC 2 6 E1 four way valve failure protection ...
Page 173: ...R32 High Efficiency DC Inverter LCAC 169 2 7 Sensor failure protection ...