Signals 

The module has two connectors: 9-pin connector X1 (table 1) for input signals and 
power connection, 10-pin connector X2 (table 2) for output signals, special signals 
and CAN-bus connection. The first pin on each connector is marked by the key.

X1.1 Hea

1

The input can be used to switch off the heater, operated in pre-heat mode, by the 
impulse of positive polarity (the input 

Heater_off

- in that case has to be connected 

to the Ground). The heater is stopped by the leading edge of the impulse. If the 
heater is idle, positive impulse on this input cancels the program start of the heater, 
programmed by DIS. 

Table 1

X1 pin 
number

Signal Name

Polarity

Wire colour

1

Hea

+

White

2

Heater_off-

-

Grey

3

He

+

Green

4

Heater_on-

-

Blue

5

Button

-

Brown

6

Boost

+

Orange

7

RC_in

+

Yellow

8

Ground

Black

9

Battery Power

Red

The signals to be necessarily connected marked in Italics

Table 2

X2 pin 
number

Signal Name

Polarity Wire colour

Maximum 

Electric Load*, 

1

RC_out

+

Blue-white

500

2

Heater_Status

-

Yellow

500

3

Alert_1

-

Grey

500

4

Alert_2

-

Orange

500

5

Timer_out

-

Blue

500

6

Indication

+

Red-white

1000

7

Sensor_In

-

Green-yellow

8

Sensor_Out

-

Green

500

9

CAN-L

Brown-white

10

CAN-H

Brown

Summary of Contents for RCP-F2

Page 1: ...Autoplugin RCP F2 Version 7 3 Technical Description User Manual Rev A...

Page 2: ...ter control by various impulses Heater status signals outputs Embedded remote control of the heater by using the original 3 button Ford car s key Remote cancellation of heater startup programmed in th...

Page 3: ...e impulse If the heater is idle positive impulse on this input cancels the program start of the heater programmed by DIS Table 1 X1 pin number Signal Name Polarity Wire colour 1 Heater_off White 2 Hea...

Page 4: ...by the leading edge of the impulse This input is suitable for the most alarm systems and GSM modules connections in order to control the heater remotely X1 5 Button The input for multi functional but...

Page 5: ...The output can be used to control an external device by time of heater operation Time of signal appearing is defined by the setting 5 1 When the heater operates for programmed time the impulse of nega...

Page 6: ...nted You can see series of double flashes in direction indicators of rear view mirrors when the heater starts to operate choose setting 6 1 2 to activate this function 3 The RCP adjusted by default on...

Page 7: ...isabling by RCP settings or in case of one time disabling by the button pressing On Running Off Boost extension On Running On This function lets the heater keep working after the engine has been switc...

Page 8: ...rresponds to a digit The LED and the direction indicators symbols in the DIS confirm each button press the LED briefly goes off the left direction indicator flashes one time when the first or the thir...

Page 9: ...lsius degrees 1 2 1 Not applied 1 2 2 Higher than 0 degrees 1 2 3 Higher than 10 degrees 1 2 4 Higher than 20 degrees 1 2 5 Higher than 30 degrees 1 2 6 Higher than 40 degrees 1 2 7 Higher than 50 deg...

Page 10: ...Lock button s function for the heater remote control 3 3 1 Heater start only 3 3 2 Start of idle heater stop of operated heater 3 4 Lock button presses count to activate the RCP module 3 4 1 Heater co...

Page 11: ...n of successful startup of the heater from remote control 6 1 1 Off 6 1 2 Series of double flashes 6 2 Indication of unsuccessful startup of the heater from remote control 6 2 1 Off 6 2 2 Series of si...

Page 12: ...Engine runs RPM impulses 7 5 6 Ventilation is on during the heater operation potential 7 5 7 Ventilation is off during the heater operation potential 7 5 8 Disable the output 8 Settings reset 8 1 1 Ap...

Page 13: ...unadjusted condition after battery discharging or disconnection See chapter Preparation for Work to adjust the heater 2 No answer from the heater followed the start command The engine is hot no need t...

Page 14: ...5 Unsuccessful start The heater was switched off spontaneously at startup Make diagnostics of the heater if the error occurs again 6 Operation cycle too short The heater was switched off spontaneousl...

Page 15: ...RCP Remote Control Plug in electronic module for the heater remote control DIS Driver Information System of the instrument cluster BHM or Boost Heat Mode operational mode of the heater when it operate...

Page 16: ...16 Autoplugin ES www autoplugin ru...

Reviews: