X2.2 Status

The assignment of this output is defined by the setting 7.5. By default the signal 
“Heater operates autonomously” is given on the output. 

X2.3 Alert_1

The signal is used to send a notification to remote control (RC should be capable to 
receive alerts). The assignment of this output is defined by the setting 7.3. When 
programmed event is occurred, the impulse of negative polarity with 1 second 
duration appears on the output. By default the signal “Heater started” is given on 
the output. 

X2.4 Alert_2

The signal is used to send a notification to remote control (RC should be capable to 
receive alerts). The assignment of this output is defined by the setting 7.4. When 
programmed event is occurred, the impulse of negative polarity with 1 second 
duration appears on the output. By default the signal “Heater stopped” is given on 
the output. 

X2.5 Timer_out

The output can be used to control an external device by time of heater operation. 
Time of signal appearing is defined by the setting 5.1. When the heater operates for 
programmed time, the impulse of negative polarity with 1 second duration appears 
on the output.

X2.6 Indication

The output can be used for connection of stand alone or button built-in indicator, 
which will inform user about heater run-time errors. 

X2.7 Sensor_In

Not used

X2.8 Sensor_Out

Not used

X2.9 CAN-L

Low-level CAN bus line has to be connected to the blue wire of Medium Speed 
CAN bus

1

.

X2.10 CAN-H

High-level CAN bus line has to be connected to the grey wire of Medium Speed 
CAN bus

1

.

1

- See installation manual for connection details

Connection 

RCP gives a possibility of quick connection to the OBD-II service connector by 
using supplied Plug-n-Play cable. Professional installation is recommended for 
connection of additional remote control. It needs at least some experience in car 
electronics installation. See installation manual for detailed connection schemes for 
various remotes.

Summary of Contents for RCP-F2

Page 1: ...Autoplugin RCP F2 Version 7 3 Technical Description User Manual Rev A...

Page 2: ...ter control by various impulses Heater status signals outputs Embedded remote control of the heater by using the original 3 button Ford car s key Remote cancellation of heater startup programmed in th...

Page 3: ...e impulse If the heater is idle positive impulse on this input cancels the program start of the heater programmed by DIS Table 1 X1 pin number Signal Name Polarity Wire colour 1 Heater_off White 2 Hea...

Page 4: ...by the leading edge of the impulse This input is suitable for the most alarm systems and GSM modules connections in order to control the heater remotely X1 5 Button The input for multi functional but...

Page 5: ...The output can be used to control an external device by time of heater operation Time of signal appearing is defined by the setting 5 1 When the heater operates for programmed time the impulse of nega...

Page 6: ...nted You can see series of double flashes in direction indicators of rear view mirrors when the heater starts to operate choose setting 6 1 2 to activate this function 3 The RCP adjusted by default on...

Page 7: ...isabling by RCP settings or in case of one time disabling by the button pressing On Running Off Boost extension On Running On This function lets the heater keep working after the engine has been switc...

Page 8: ...rresponds to a digit The LED and the direction indicators symbols in the DIS confirm each button press the LED briefly goes off the left direction indicator flashes one time when the first or the thir...

Page 9: ...lsius degrees 1 2 1 Not applied 1 2 2 Higher than 0 degrees 1 2 3 Higher than 10 degrees 1 2 4 Higher than 20 degrees 1 2 5 Higher than 30 degrees 1 2 6 Higher than 40 degrees 1 2 7 Higher than 50 deg...

Page 10: ...Lock button s function for the heater remote control 3 3 1 Heater start only 3 3 2 Start of idle heater stop of operated heater 3 4 Lock button presses count to activate the RCP module 3 4 1 Heater co...

Page 11: ...n of successful startup of the heater from remote control 6 1 1 Off 6 1 2 Series of double flashes 6 2 Indication of unsuccessful startup of the heater from remote control 6 2 1 Off 6 2 2 Series of si...

Page 12: ...Engine runs RPM impulses 7 5 6 Ventilation is on during the heater operation potential 7 5 7 Ventilation is off during the heater operation potential 7 5 8 Disable the output 8 Settings reset 8 1 1 Ap...

Page 13: ...unadjusted condition after battery discharging or disconnection See chapter Preparation for Work to adjust the heater 2 No answer from the heater followed the start command The engine is hot no need t...

Page 14: ...5 Unsuccessful start The heater was switched off spontaneously at startup Make diagnostics of the heater if the error occurs again 6 Operation cycle too short The heater was switched off spontaneousl...

Page 15: ...RCP Remote Control Plug in electronic module for the heater remote control DIS Driver Information System of the instrument cluster BHM or Boost Heat Mode operational mode of the heater when it operate...

Page 16: ...16 Autoplugin ES www autoplugin ru...

Reviews: