● Pressure measurement of any gas, liquid or oil [Fluid type]

   (

except substances which may corrode stainless steel 316L) 

● Simultaneous display of present value (PV) and set value (SV) 

    

Selectable SV, pressure unit, or none display for SV display part 

● Selectable NPN, PNP open collector output by parameter setting

● 3 colors for PV display part (run mode: red or green / setting mode: orange) 

● 12-segment LCD display for easier value reading

●  Measurement range: -100.0 to 100.0kPa, -100 to 1,000kPa  

(pneumatic type: compound pressure, fluid type: sealed gauge pressure)

● Analog output: voltage (1-5VDC), current (DC4-20mA)

● Parameter copy function

● Option input/output: auto shift, remote zero, hold (only for PSQ-

 

 

C

 

 

 

U

 

-

 

)

● Forced output control mode for device testing and maintenance

● Min. display unit: 0.1kPa, 1kPa (variable by model)

● One-touch connector type for easy wiring and maintenance

● Password setting for SV 

Compact, Dual LCD Display Digital Pressure Sensor

E.g.)  For calculating 760mmHg to kPa : According to above chart, 1mmHg is 0.133322kPa,  

therefore 760mmHg will be 760×0.133322kPa=101.32472kPa.

 Features

 Pressure Conversion Chart

to

from 

Pa 

kPa 

MPa 

kgf/cm

2

mmHg

mmH

2

O

psi 

bar 

inHg 

1Pa

1

0.001

0.000001 

0.000010197 0.007501

0.101972

0.000145038 0.00001

0.0002953

1kPa

1000.000 

0.001 

0.010197 

7.500617 

101.971626 0.145038 

0.01 

0.2953 

1MPa

1000000

1000

1

10.197162

7500.61683 101971.626 145.038243 10

295.299875

1kgf/cm

2

98066.5

98.0665 

0.098067

735.55924  10000.0005  14.223393  0.980665 

28.959025 

1mmHg

133.322368  0.133322 

0.000133 

0.001359 

13.595099  0.019337 

0.001333 

0.039370 

1mmH

2

O

9.80665 

0.009807

-

0.000099 

0.073556 

0.00142 

0.000098 

0.002896

1psi 

6894.733 

6.89473 

0.006895

0.070307 

51.714752  703.016716  1 

0.068947 

2.036014 

1bar 

100000.0 

100.0000 

0.100000 

1.019716

750.062 

10197.1626 14.503824

29.529988

1inHg 

3386.388

3.386388 

0.003386 

0.034532 

25.40022 

345.315507  0.491156 

0.033864 

Pneumatic type

Fluid type

 Ordering Information

Pressure port

Option Input/Output

Cable

Pressure range

Applicable fluid

Applicable fluid

Appearance

Item

                Applied fluid

Pressure port

Pneumatic type

Fluid type

Rc1/8

R1/8

NPT1/8

-

R1/4

-

NPT1/4

-

9/16-18UNF

-

No mark

NPN or PNP open collector output

U

NPN or PNP open collector

analog output or external input type

No mark

Cable type

C

Connector type

01

100kPa

1

1,000kPa

C

Compound pressure 

No mark

Pneumatic type (air, non-corrosive gas)

B

Fluid type (gas, liquid, oil)

Q

Regular square type (30×30mm), dual display

PS

Pressure Sensor

PS

C

Q

01 C

Rc1/8

Please read “Safety Considerations” 

in the instruction manual before using.

Summary of Contents for PSQ Series

Page 1: ...60 0 133322kPa 101 32472kPa Features Pressure Conversion Chart to from Pa kPa MPa kgf cm2 mmHg mmH2O psi bar inHg 1Pa 1 0 001 0 000001 0 000010197 0 007501 0 101972 0 000145038 0 00001 0 0002953 1kPa 1000 000 1 0 001 0 010197 7 500617 101 971626 0 145038 0 01 0 2953 1MPa 1000000 1000 1 10 197162 7500 61683 101971 626 145 038243 10 295 299875 1kgf cm2 98066 5 98 0665 0 098067 1 735 55924 10000 0005...

Page 2: ...0ms 500ms 1 000ms 5 000ms Protection circuit Output short over current protection circuit Analog output 3 Voltage output Output voltage 1 5VDCᜡ 2 5 F S Linear max 1 F S Resolution 1 2 000 Output impedance approx 240Ω Response time 50ms Current output Output current DC4 20mA 2 5 F S Linear max 1 F S Resolution 1 2 000 Output impedance approx 100kΩ Response time 50ms External input 3 Auto shift Remo...

Page 3: ...y for over 4 sec to enter parameter 2 group Setting mode Press the M key to select the setting items Press the M key for over 2 sec to return RUN mode 5 key RUN mode Press the key to set preset value of output operation mode Press the M keys to set key lock unlock Press the keys to adjust zero point Press the M keys to set peak hold Preset value setting mode Press the key to increase decrease sett...

Page 4: ...ss 0 5 to 7mm 31 0 0 4 When N units are installed in series 31 0 0 4 31 N 3 5 N 1 Min 55 Integrated installation set Pneumatic Fluid type Separate installation set Pneumatic type 28 2 40 30 40 42 35 26 3 20 25 8 Rear panel bracket Front panel bracket Front cover PSO P01 Front cover PSO P02 Panel cut out Front Rear pael bracket set PSO B04 Panel bracket PSO B02 Panel cut out 6 75 7 37 41 34 2 42 39...

Page 5: ...own V blue 0V black OUT1 white OUT2 12 24VDC orange analog output external input Load Load RUN mode Preset value setting Zero point adjustment Parameter 2 group Key lock High Low peak hold for over 1 sec It sets reference pressure to the current atmospheric pressure as zero for over 1 sec for over 1 sec Output short over current protection circuit Output short over current protection circuit Outpu...

Page 6: ...ld The function to hold present value PV and control output while signal is input When OUT1 operation mode is set as fOUT or applied pressure is higher lower than the display pressure range auto shift SHFT remote zero ZERO functions are not available A V ShOT 1 Auto shift applied terminal OUT1 OUT2 ALL OUT1 OUT2 OUT1 OUT2 Select auto shift applied terminal Appears when Analog output External input...

Page 7: ... Only checking parameters 0000 sOUT Control output switching NPN PNP NPN PNP Select type of control output NPN HYS Hysteresis for easy mode 1 to 1 1 1 1 1 1 1 1 Bar type Min 1ea Max 8ea Set the hysteresis for easy mode Rated pressure range Hysteresis per 1 Bar 100 0 to 100 0kPa 0 1kPa 100 0 to 1 000kPa 1kPa Appears when OUT1 or OUT2 operation mode is easy mode Although the display unit is changed ...

Page 8: ...setting by output operation mode Output operation mode Preset Setting range Factory default 100 0 to 100 0kPa 100 to 1 000kPa EASY Easy P Pressure detection level Min display pressure P Max display pressure 05 0 0500 HYsM Hysteresis ST Pressure detection level Min display pressure ST Max display pressure 05 0 0500 HYS Hysteresis level Min display pressure HYS ST 5 0 0000 WIN Window com parison LO ...

Page 9: ...tput voltage or current and external input auto shift remote zero hold are not available at the same time Analog output A V Analog voltage output A C Analog current output External input SHFT Auto shift ZERO Remote zero HOLD Hold Preset setting by external input mode External input mode Preset Setting range Factory default SHFT Auto shift ShIN Auto shift correction value Min preset setting value S...

Page 10: ...1 ST2 Hysteresis is fixed as Min display interval The pressure detection level SET is shown in the below formula ST1 ST2 2 SET Pressure 1 Min display interval 1 1 1 ST1 ST2 SET SET ST1 ST2 OUT1 N O OUT2 N O OUT1 N C OUT2 N C ST2 SET ST1 ON OFF ON OFF ON OFF ON OFF Time Time Time Time Time Forced output control mode fOUT RUN mode fOUT Regardless of setting value it maintains comparison output OFF a...

Page 11: ...COPY Slave unit PV display arbitrary value SV display OK M Master Slave brown V blue 0V black OUT1 black OUT1 white OUT2 white OUT2 Auto Shift Remote Zero Hold input Output mode change OUT1 operation mode There are 4 kinds of control output mode in order to realize the various pressure detection Hysteresis mode HYsM When needed to change hysteresis for detecting pressure Window comparison output m...

Page 12: ...the SV display part in RUN mode There are 3 types displaying SV STD displaying unit UNIT none OFF RESET This function is to reset all parameters as factory default except control output SV to prevent wrong settings or difficult operation Password This function is to limit parameter settings to check the parameter or to change the parameter settings only for entering the set password 0000 Password ...

Page 13: ...t this unit must avoid direct touch with water oil thinner etc 5 PSQ Series has panel bracket PSO B02 front cover PSO P01 are sold separately When mounting the unit on panel please follow the below figure The tightening torque of one touch fitting should be max 10N m It may cause mechanical problems Front cover PSO P01 Mounting panel panel thickness 0 8 3 5mm Panel bracket PSO B02 Body PSQ SMPS F ...