-|Transparent Guide|-

Output Mode

Output mode is available to set. (Indicator does not support output mode.)

OFF:

ON:

H:

 hysteresis

  

■ S (Standard) output 

mode

  

■ H (High) output 

mode

• Comparative value setting condition: 

individual o

ut

put operation regardless of 

size or order of set comparative values

• Comparative value setting condition: 

individual o

ut

put operation regardless of 

size or order of set comparative values

HH output:  Display value

≥ Comparative value HH

H output: 

Display value

≥  Comparative value H

L output: 

Display value

≤  Comparative value L

LL output:  Display value

≤  Comparative value LL

GO output:  No HH, H, L, LL output

Comp

ar

ative

 

value

HH

H

L

LL

HH

H

GO

L

LL

Output

H

H

H

H

HH output:  Display value

≥ Comparative value HH

H output: 

Display value

≥  Comparative value H

L output: 

Display value

≥ Comparative value L

LL output:  Display value

≥  Comparative value LL

GO output:  No HH, H, L, LL output

Comp

ar

ative

 

value

Output

HH

H

L

LL

HH

H

L

LL

GO

H

H

H

H

  

■ L (Low) output 

mode

  

■ B (Block) output 

mode

• Comparative value setting condition: 

individual o

ut

put operation regardless of 

size or order of set comparative values

• Comparative value setting condition: 

LL<L<H<HH

HH output:  Display value

≤  Comparative value HH

H output: 

Display value

≤  Comparative value H

L output: 

Display value

≤  Comparative value L

LL output:  Display value

≤   Comparative value LL

GO output:  No HH, H, L, LL output

Comp

ar

ative

 

value

Output

HH

H

L

LL

HH

H

L

LL

GO

H

H

H

H

HH output:  Display value

≥ Comparative value HH

H output:  Comparative value HH > Display value ≥ 

Comparative value H

L output:  Comparative value LL < Display value ≤ 

Comparative value L

LL output:  Display value

≤  Comparative value LL

GO output:  No HH, H, L, LL output

Comp

ar

ative

 

value

Output

HH

H

L

LL

HH

H

GO

L

LL

H

H

H

H

  

■ I (One-shot) output 

mode

  

■ F (Deflection) output 

mode

• Comparative value setting condition: 

individual o

ut

put operation regardless of 

size or order of set comparative values

• One-shot output time: 0.3 sec (fixed)
• No GO output. 
• No hysteresis.

HH output:  Display value

≥ Comparative value HH

H output:  Comparative value HH > Display value ≥ 

Comparative value H

L output:  Comparative value H > Display value ≥ 

Comparative value L

LL output:  Comparative value L > Display value ≥ 

Comparative value LL

0.3s

0.3s

0.3s

0.3s

HH

H

L

LL

HH

H

GO

L

LL

Comp

ar

ative

 

value

Output

• Transmits outputs when the saved 

setting value exceeds H deviation or L 
deviation.

• Comparative value setting 

:  Based on the set value, set the H / L  

deviation in the P0-2, P2-7 H 
comparative value and P0-3, P2-8 L 
comparative value parameters. 
( The set deviation value is saved during 

Power OFF until it is re-set.)

• Comparative value setting range 

: 0.0001 to 99999 
The setting range is different according 
to the P2-2 Decimal point position of 
display value setting. 

E.g.)  

In case of P2-2 Decimal point 
position of display value = 0000.0,  
setting range = 0.1 to 9999.9

• Saving setting value: [MODE] + [▲] 
• Checking setting value: [▲]
• No HH, GO, LL output.
• The deviation can be set to “0” but the 

actual operation will be the same as “1”.

01)

02)

(Max.)H deviation

SV

(Min.) L deviation

Power

Save SV

L deviation

output

H deviation

output

Save SV

01) When P1-6 Delay monitoring = F.DEFY is set, there is 

no output.

02) The graph is assuming that there is a saved setting 

value prior to the setting value save point. The actual 

output position may be different.

Operation Mode

  

■ F1: frequency / revolutions / speed

Measures the frequency of input A and displays the calculated frequency, revolutions, 
and speed.

Frequency (Hz)

= f × α

(α = 1 [sec])

Revolutions (rpm) = f × α

(α = 60 [sec])

Speed (m / min)

= f × α

(α = 60 L [sec])

•  L:  travel distance of conveyor belt of 1 

cycle [m]

•  α:  prescale value  

(For multiple objects, α = 60L / N) 

Display value Display

 unit

α

Frequency

Hz

1

kHz

0.001

Revolutions

rps

1

rpm (default)

60

Speed

mm / sec

1,000 L

cm / sec

100 L

m / sec

1 L

m / min

60 L

km / hour

3.6 L

MP5

MP5

Encoder

t1

t2

t3

t4

t5

t6

Input A

Hold

Display

1  × α

t1

1 × α

t2

1 × α

t5

1 × α

t3

1 × α

t6

  

F2: 

passing speed

Displays the passing speed between input A ON and input B ON.

Passing speed (V) = f × α

(α = L [m])

•  f :  reciprocal of time [sec] between input A 

(sensor) ON and input B( sensor) ON.

•  L:  distance between input A (sensor) and 

input B (sensor) [m]

•  α: prescale value 

Display value Display

 unit

α

Passing speed

mm / sec

1,000 L

cm / sec

100 L

m / sec (default) 1 L
m / min

60 L

km / hour

3.6 L

Sensor A

Sensor B

MP5

•  ta: Return time (≥ 20 ms)

Input A

Input B

Hold

Display

t1

ta

t2

t3

t4

t5

t6

t7

1 × α

t1 

1 × α

t2 

1 × α

t3

1 × α

t6

1 × α

t4

1 × α

t7

  

F3: cycle

Displays the measured time from input A ON to the next ON.

Cycle (T)

= t

•  t: measurement time [sec]

Display value Display

 unit

Cycle

SEC

MIN

999.99 s 

(default)

999.99 m

9999.9 s

9999.9 m

99 m 59.9 s

99 h 59.9 m

9 h 59 m 59 s

999 h 59 m

99999 s

99999 m

Photoelectric 

sensor

MP5

Input A

t1

t1

t2

t2

t3

t5

t6

t3

t4

t5

t6

Hold

Display

  

F4: 

passing time

Measure the time from input A ON to the next ON, and displays the passing time of the 
arbitrary distance.

Passing time [sec] = t × α

 (α= 

L [m] 

 Distance advanced in 1 pulse cycle [m] )

•  t: measurement time [sec]
•  L: arb

i

trary distance [m]

•  α: prescale value

Display value Display

 unit

Passing time

SEC

MIN

999.99 s 

(default)

999.99 m

9999.9 s

9999.9 m

99 m 59.9 s

99 h 59.9 m

9 h 59 m 59 s

999 h 59 m

99999 s 

99999 m

MP5

L : Dis

tanc

e [m]

Input A

t1

t1 × α t2 × α

t5 × α

t2

t3 × α

t6 × α

t3

t4

t5

t6

Hold

Display

Summary of Contents for MP5S Series

Page 1: ...instruction may result in fire or electric shock 04 Do not connect repair or inspect the unit while connected to a power source Failure to follow this instruction may result in fire or electric shock...

Page 2: ...Master It is the comprehensive device management program for Autonics products providing parameter setting monitoring and data management Manual For proper use of the product refer to the manuals and...

Page 3: ...rical 100 000 operations 250 VAC 3 A 30 VDC 3 A resistive load switching frequency 20 operations min Insulation resistance 100 M 500 VDC megger Dielectric strength 2 000 VAC 60 Hz for 1 min Noise immu...

Page 4: ...each parameter it returns to RUN mode MODE key Saves current setting value and moves to the next parameter key Checks fixed value Changes setting digits key Changes setting values Parameter 0 group P...

Page 5: ...P0 3 P2 8 L comparative value parameters The set deviation value is saved during Power OFF until it is re set Comparative value setting range 0 0001 to 99999 The setting range is different according...

Page 6: ...B prescale value of input B Conveyor A Conveyor B MP5 Display value Display unit Error ratio Input A fA fB Input B Hold When the hold signal turns ON the display value is maintained until the display...

Page 7: ...setting value the output may turn ON OFF frequently and unstably To prevent this hysteresis value is set based on the comparative setting value Comparative value H HH Comparative value L LL A A Outpu...

Page 8: ...A A S S A A S S B B T T B B T T B B T T B B T T C C U U C C U U C C U U C C U U D D V V D D V V D D V V D D V V E E W W E E W W E E W W E E W W F F X X F F X X F F X X F F X X G G Y Y G G Y Y G G Y Y...