DRW160458AJ

Multi Pulse Meters

MP5S / MP5Y / MP5W Series

PRODUCT MANUAL

For your safety, read and follow the considerations written in the instruction 
manual, other manuals and Autonics website.

The specifications, dimensions, etc. are subject to change without notice for product 
improvement. Some models may be discontinued without notice. 

Features

• 16 operation modes  

- Frequency / revolutions / speed, passing speed, cycle, passing time, time interval 
- Time differential, absolute ratio, error ratio, density, error, length measurement 1 / 2, 
   interval 
- Accumulation, addition / subtraction (individual input),  
  addition / subtraction (phase difference input)

• Various output models 

- Relay triple / quintuple output, NPN / PNP open collector quintuple output 
- BCD Dynamic output, PV transmission output (current output) 
- RS485 communication output (Modbus RTU)

• Various function  

-  Prescale, delay monitoring, hysteresis, auto-zero, parameter lock, data bank (MP5W 

only)

• Display range: -19999 to 99999
• Various display units 

ᜢ ᜧ ᜫ

Safety Considerations

• Observe all ‘Safety Considerations’ for safe and proper operation to avoid hazards.
• ᜸ symbol indicates caution due to special circumstances in which hazards may occur.

᜸ Warning

  

Failure to follow instructions may result in serious injury or death.

01. Fail-safe device must be installed when using the unit with machinery that 

may cause serious injury or substantial economic loss. (e.g. nuclear power 

control, medical equipment, ships, vehicles, railways, aircraft, combustion 

apparatus, safety equipment, crime / disaster prevention devices, etc.)

Failure to follow this instruction may result in personal injury, economic loss or 

fire.

02. Do not use the unit in the place where flammable / explosive / corrosive gas, 

high humidity, direct sunlight, radiant heat, vibration, impact, or salinity 

may be present.

Failure to follow this instruction may result in explosion or fire.

03. Install on a device panel to use.

Failure to follow this instruction may result in fire or electric shock.

04. Do not connect, repair, or inspect the unit while connected to a power 

source.

Failure to follow this instruction may result in fire or electric shock.

05. Check ‘Connections’ before wiring.

Failure to follow this instruction may result in fire.

06. Do not disassemble or modify the unit.

Failure to follow this instruction may result in fire or electric shock.

᜸ Caution

  

Failure to follow instructions may result in injury or product damage.

01. When connecting the power / measurement input and relay output, use 

AWG 24 (0.20 mm

2

) to AWG 15 (1.65 mm

2

) cable and tighten the terminal 

screw with a tightening torque of 0.98 to 1.18 N m. 

 

Use the wiring suitable for the load current capacity.

Failure to follow this instruction may result in fire or malfunction due to contact 

failure.

02. Use the unit within the rated specifications.

Failure to follow this instruction may result in fire or product damage.

03. Use dry cloth to clean the unit, and do not use water or organic solvent.

Failure to follow this instruction may result in fire or electric shock.

04. Keep the product away from metal chip, dust, and wire residue which from 

flowing into the unit.

Failure to follow this instruction may result in fire or product damage.

Cautions during Use

• Follow instructions in ‘Cautions during Use’.  

Otherwise, it may cause unexpected accidents.

• Power supply should be insulated and limited voltage / current or Class 2, SELV power 

supply device.

• Install a power switch or circuit breaker in the easily accessible place for supplying or 

disconnecting the power.

• Use twisted pair wire for communication line.

• Keep away from high voltage lines or power lines to prevent inductive noise.  

In case installing power line and input signal line closely, use line filter or varistor 

at power line and shielded wire at input signal line. Do not use near the equipment 

which generates strong magnetic force or high frequency noise.

• This unit may be used in the following environments. 

- Indoors (in the environment condition rated in ‘Specifications’) 

- Altitude max. 2,000 m 

- Pollution degree 2 

- Installation category II

Summary of Contents for MP5S Series

Page 1: ...instruction may result in fire or electric shock 04 Do not connect repair or inspect the unit while connected to a power source Failure to follow this instruction may result in fire or electric shock...

Page 2: ...Master It is the comprehensive device management program for Autonics products providing parameter setting monitoring and data management Manual For proper use of the product refer to the manuals and...

Page 3: ...rical 100 000 operations 250 VAC 3 A 30 VDC 3 A resistive load switching frequency 20 operations min Insulation resistance 100 M 500 VDC megger Dielectric strength 2 000 VAC 60 Hz for 1 min Noise immu...

Page 4: ...each parameter it returns to RUN mode MODE key Saves current setting value and moves to the next parameter key Checks fixed value Changes setting digits key Changes setting values Parameter 0 group P...

Page 5: ...P0 3 P2 8 L comparative value parameters The set deviation value is saved during Power OFF until it is re set Comparative value setting range 0 0001 to 99999 The setting range is different according...

Page 6: ...B prescale value of input B Conveyor A Conveyor B MP5 Display value Display unit Error ratio Input A fA fB Input B Hold When the hold signal turns ON the display value is maintained until the display...

Page 7: ...setting value the output may turn ON OFF frequently and unstably To prevent this hysteresis value is set based on the comparative setting value Comparative value H HH Comparative value L LL A A Outpu...

Page 8: ...A A S S A A S S B B T T B B T T B B T T B B T T C C U U C C U U C C U U C C U U D D V V D D V V D D V V D D V V E E W W E E W W E E W W E E W W F F X X F F X X F F X X F F X X G G Y Y G G Y Y G G Y Y...