20
Axess® Pro Series 1101
Owner Installation Instructions
Menu 4. Lock Times
With the addition of a relay module connected to the control board, the electric lock can be controlled. Lock
output can be programmed for both hold and pulse operation and can also be programmed to activate prior
to the door motor starting. The operation of the lock can be programmed to behave differently on open cycles
to that on close cycles.
Control Board Adjustments
Parameter
Min
Max
Default
Step
Unit
Menu No.
OPEN LOCK TIME Set the time the lock is
activated for on open cycles
0.0
Hold
0.5
0.1
Sec
4
CLOSE LOCK TIME Set the time the lock is
activated for on close cycles
0.0
Hold
0.5
0.1
Sec
4
PRE-OPEN LOCK TIME
Time the lock is activated for prior to opening
0.0
25.5
0.0
0.1
Sec
4
PRE-CLOSE LOCK TIME
Time the lock is activated for prior to closing
0.0
25.5
0.0
0.1
Sec
4
Menu 5. Light Times
With the addition of a relay module connected to the control board, a light can be controlled. The time the
light stays on is controlled by two timers. The fi rst times the length of time the light is activated for prior to a
drive cycle. This is used to warn that door movement is pending. The second times how long the light remains
on after a cycle. The parameters are shown below.
Parameter
Min
Max
Default
Step
Unit
Menu No.
ON AFTER CYCLE LIGHT TIME
Time light remains on for after a cycle
0
255
60
1
Sec
5
ON BEFORE OPEN CYCLE LIGHT TIME
Minimum time light is activated for prior to
opening
0
25.5
0
0.1
Sec
5
ON BEFORE CLOSE CYCLE LIGHT TIME
Minimum time light is activated for prior to
closing
0
25.5
0
0.1
Sec
5