Owner Installation Instructions
Axess® Pro Series 1101
15
Pedestrian Access Position
After completing the travel limit set procedure, the
Pedestrian Access Position is automatically set to a
position which is in the middle of the door travel. The
position can be manually set by following the SETTING
PEDESTRIAN POSITION procedure below.
NOTE:
Before setting the Pedestrian Access Position,
the door must be in the fully closed position. As with
the Setting Travel Limit procedure, a transmitter can
be used to complete the pedestrian position setting
procedure.
Step 1. Navigating to “Set Pedestrian
Menu”
Press PREV to navigate to Menu 10.
Press SET - MENU 10.1 is displayed.
Press NEXT to go to MENU 10.2.
Press SET to enter Set Pedestrian procedure
(Fig.
18)
.
Step 2. Setting Pedestrian Position
Press OPEN to move the door to the desired
pedestrian access position. (Or press button 1 on
transmitter)
(Fig. 19).
Press SET to record position. (Or press button 2 on
transmitter).
Step 3. Pedestrian Position Set
The controller will return to the MAIN SCREEN with
the door status shown as being in pedestrian access
mode
(Fig. 20).
1.
2.
3.
4.
1.
2.
Setting Pedestrian Position
MENU 10.2
Set Pedestrian
18
fi g
20
fi g
OR
E S
To Pedestrian
Position,
SET
Ped’n Access
Press<-->to Acess Menus
19
fi g
The variable frequency inverter converts 240V single
phase power into three phase to run the drive motor.
The other main function is to control the soft start/soft
stop (accelerate/decelerate) speed. The table below
indicates the factory preset and the range.
To change the accelerate/decelerate speed.
Press DSP/FUN button to display F06. ( Fig. 21)
Press DATA/ENT to enter modify mode. Display
should show factory default - 50Hz.
Press
▲
or
▼
to increase or decrease the
frequency .
Press DATA/ENT to set.
Function
FN
Unit
Range
Default
Accel./
Decel.
Speed
6
0.1Hz
30-70Hz
50Hz
1.
2.
3.
4.
Setting Operating Speed
21
fi g
50.0