-3-
Model 400 Installation & Operation Manual
Calculating Chlorine Concentration Per Pump Cycle
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Approximate
Model 400 Feeder Cl
2
Concentration Per
Pump Cycle for a 42 Gallon Pressure Tank.
1 = 2 PPM
A = 3.5 PPM
2 = 8 PPM
B = 13 PPM
3 = 30 PPM
C = 40 PPM
OFF = 60+ PPM
If Using an 82 Gallon Pressure Tank Divide the PPM By 2
If Using a 20 Gallon Pressure Tank Multiply the PPM By 2
CHLORINE–(Cl
2
) PPM
IRON – (Fe) x (.64 Cl
2
)
HYDROGEN SULFIDE – (H
2
S) x (2.2 Cl
2
)