background image

-1-

Model 400 Installation & Operation Manual

Installation & Operation Information

The 

Model 400 feeder will operate on a varying pressure 

such as a home well system or on a constant pressure 

such as a sprinkler or pool system.
When used as a varying pressure system the non-function-

ing valve (No. 11) must be in place as received. A charcoal 

filter must follow the 

Model 400 feeder on a varying 

pressure system for proper operation. Tests have shown 

that one cube of coconut shell activated carbon is the best 

carbon to use (grade 9/50, mesh· 8/30).
There are seven positions for varying the amount of 

chemical feed. Rotate the top cap (No. 7) so there is a 

hole showing through the level desired. There are two hole 

selections for each hole in the cap (No. 7).
The smaller hole will dispense the greatest amount and 

selecting a lower hole on the cap will increase the output.
Approximate chlorine readings using a 42 gallon pressure 

tank out of the 

Model 400 feeder ·per pump cycle in PPM, 

for each hole are; 1=2, A=3.5, 2=:=8, B=l3, 3=30, 

C=40 and with no holes showing, the off position is 60 

plus.
These readings are obtained with no iron or hydrogen 

sulfide using the chlorine. Variables that will change the 

dilution are: pressure tank size, large volumes of water 

flow while the pump is building pressure to shut off, horse 

power of the pump, and a water logged pressure tank or 

air pressure is low or high in the air bag. 

The 

Model 400 

feeder will dispense the same amount of chemical for each 

cycle of the pump from maximum to minimum pressure.

When used on a constant-pressure and flow it is neces-

sary to replace the valve (No.11). Replace it with the 

optional adjustable valve (No. 20). It may be necessary to 

install the optional screen filters (No. 19) in the top inside 

hole of (No. 8) and screen (No. 18) in the adjustable inlet 

hole when using chemicals other than chlorine, When 

using the unit for constant pressure and flow such as a 

sprinkler system or pool; install the unit on the output to 

the sprinkler heads or on the return line to the pool. The 

adjustments for the constant pressure system should have 

no holes shown through in the off position. The amount of 

chemical dispensed is controlled with the adjustable rate 

of feed valve on the outside of the unit. It may be neces-

sary to adjust the unit if flow is increased or decreased.

DANGER:  Do Not Mix Different Types or Brands of Chlorine, an Explosion Can Occur.

DECLORINATION 

FILTER

PUMP

IRRIGATION 

VALVE

CHECK

VALVE

SHUT-OFF 

VALVE

DRAIN VALVE

400 FEEDER

WELL

PRESSURE TANK

SOFTENER & 
BRINE TANK

(Actual size of the 

Model 400 Feeder - 10.5'' high X 11.5'' long) (Empty weight - 6.5 lbs.)

MAXIMUM TESTED PRESSURE IS 80 LBS.
U.S. PATENT NOS. 5,053,206; 4,908,190;  

4,548,228; 4,407,322

NOTE:  

Install a Check Valve After the Pressure 

Tank For Heavy Use of an Irrigation Valve.

CAUTION:  

Use Only Calcium Hypochlorite 

Chlorine Tablets For Potable Water.

Summary of Contents for 400

Page 1: ...Installation Operation Information Non Electric Dry Chlorine Pellet Feeder Model 400 Automated Pure Water ...

Page 2: ...ICE OF THE MODEL 400 FEEDER FOR ANY LOSS DAMAGE OR INJURY TO PERSON OR PROPERTY INCLUDING ANY SUCH LOSS DAMAGE OR INJURY ATTRIBUTABLE TO MANUFACTURER S NEGLIGENCE OR FAULT AND INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES from a the design manufacture sale delivery installation repair operation or use of the Model 400 feeder or any part thereof b any actual or alleged failure or defect in the ...

Page 3: ...ter logged pressure tank or air pressure is low or high in the air bag The Model 400 feeder will dispense the same amount of chemical for each cycle of the pump from maximum to minimum pressure When used on a constant pressure and flow it is neces sary to replace the valve No 11 Replace it with the optional adjustable valve No 20 It may be necessary to install the optional screen filters No 19 in ...

Page 4: ...e the fluid if needed The chemical solution out is controlled with the optional rate of feed valve in a constant pressure system To oxidize one PPM of Hydrogen Sulfide H2S it takes 2 2 PPM of Chlorine Cl2 To oxidize 1 PPM of Iron Fe it takes 64 PPM of Cl2 Example If you have 4 PPM of Fe and 1 PPM of H2S look on the vertical portion of the graph labeled PPM and start at 4 and move horizontal to the...

Page 5: ... 12 13 14 15 Approximate Model 400 Feeder Cl2 Concentration Per Pump Cycle for a 42 Gallon Pressure Tank 1 2 PPM A 3 5 PPM 2 8 PPM B 13 PPM 3 30 PPM C 40 PPM OFF 60 PPM If Using an 82 Gallon Pressure Tank Divide the PPM By 2 If Using a 20 Gallon Pressure Tank Multiply the PPM By 2 CHLORINE Cl2 PPM I R O N F e x 6 4 C l 2 HYDROGEN SULFIDE H2S x 2 2 Cl2 ...

Page 6: ...umber or letter directly under it as per figure 1 The hole in the tube should show in the center of the hole in the cap Hole Settings in Parts Per Million CBA 3 2 1 UNIT MUST BE INSTALLED AFTER THE PRESSURE TANK CAUTION When Draining Chlorine Chlorine Can Bleach Clothing May Burn Eyes Skin PVC BALL VALVE DRAIN VALVE TO RELIEVE PRESSURE AND DRAIN UNIT 400 FEEDER PVC BALL VALVE U S PATENT NOS 5 053 ...

Page 7: ...ot add water to the unit or operation will be inhibited It may take a few pump cycles before chlorine is dispensed 6 Replace top No 4 and close drain valve 7 Tum on water NOTES If unit is opened after pressurization it is neces sary to drain fluid to the bottom of cap No 7 before repressurizing or operation will be inhib ited If unit is used for odor removal do not refill until odor returns to min...

Page 8: ... a smaller tank such as a 20 gallon tank cut the chlorine output by one half The Model 400 feeder will output the same amount of chemical for each pump cycle and a smaller tank is delivering less water on each pump cycle increasing the chemical concentration High odor and or Unit appears not to be dispensing the proper amount of chemical 1 Unit needs chlorine or it is over filled Max 3 4 full 2 Wr...