background image

-4-

Model 400 Non-Electric Dry Chlorine Pellet Feeder

Chlorine Setting in PPM for Center Tube & Cap

HOLE # 1 = 2 PPM 

HOLE # A = 3 .5 PPM

HOLE # 2 = 8 PPM 

HOLE # B = 13 PPM

HOLE # 3 = 30 PPM 

HOLE # C = 40 PPM

All Holes Closed Will Deliver 

60 PPM Per Pump Cycle.

This chart is for a 42 gallon or equivalent pressure tank. 

When using an 80 gallon pressure tank, the PPM amount 

will be 50% less per pump cycle. A 20 gallon pressure tank 

will yield 2 times the amount. 
Each number or letter will show a different hole in the cap. 

Line up the 3 holes in the cap with the proper number or 

letter directly under it (as per figure 1). The hole in the tube 

should show in the center of the hole in the cap.

Hole Settings in Parts Per Million

CBA  3  2  1

UNIT MUST BE INSTALLED AFTER THE PRESSURE TANK

CAUTION:  When Draining Chlorine, Chlorine Can Bleach Clothing & May Burn Eyes & Skin. 

PVC BALL 

VALVE

DRAIN VALVE TO 

RELIEVE PRESSURE, 

AND DRAIN UNIT 

400 

FEEDER

PVC BALL 

VALVE

U.S. PATENT NOS.  

5,053,206; 4,908,190;  

4,548,228; 4,407,322

Center Tube Must be Removed and Cleaned Each Time 

Before Refilling.

 (See filling information #3)

When removing center tube for cleaning, check hole set-

ting in cap.

After cleaning, be sure the setting is the same before 

replacing cap.

Install PVC Check Valve Before Feeder if Untreated 

Water is Used Before Feeder

.

Summary of Contents for 400

Page 1: ...Installation Operation Information Non Electric Dry Chlorine Pellet Feeder Model 400 Automated Pure Water ...

Page 2: ...ICE OF THE MODEL 400 FEEDER FOR ANY LOSS DAMAGE OR INJURY TO PERSON OR PROPERTY INCLUDING ANY SUCH LOSS DAMAGE OR INJURY ATTRIBUTABLE TO MANUFACTURER S NEGLIGENCE OR FAULT AND INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES from a the design manufacture sale delivery installation repair operation or use of the Model 400 feeder or any part thereof b any actual or alleged failure or defect in the ...

Page 3: ...ter logged pressure tank or air pressure is low or high in the air bag The Model 400 feeder will dispense the same amount of chemical for each cycle of the pump from maximum to minimum pressure When used on a constant pressure and flow it is neces sary to replace the valve No 11 Replace it with the optional adjustable valve No 20 It may be necessary to install the optional screen filters No 19 in ...

Page 4: ...e the fluid if needed The chemical solution out is controlled with the optional rate of feed valve in a constant pressure system To oxidize one PPM of Hydrogen Sulfide H2S it takes 2 2 PPM of Chlorine Cl2 To oxidize 1 PPM of Iron Fe it takes 64 PPM of Cl2 Example If you have 4 PPM of Fe and 1 PPM of H2S look on the vertical portion of the graph labeled PPM and start at 4 and move horizontal to the...

Page 5: ... 12 13 14 15 Approximate Model 400 Feeder Cl2 Concentration Per Pump Cycle for a 42 Gallon Pressure Tank 1 2 PPM A 3 5 PPM 2 8 PPM B 13 PPM 3 30 PPM C 40 PPM OFF 60 PPM If Using an 82 Gallon Pressure Tank Divide the PPM By 2 If Using a 20 Gallon Pressure Tank Multiply the PPM By 2 CHLORINE Cl2 PPM I R O N F e x 6 4 C l 2 HYDROGEN SULFIDE H2S x 2 2 Cl2 ...

Page 6: ...umber or letter directly under it as per figure 1 The hole in the tube should show in the center of the hole in the cap Hole Settings in Parts Per Million CBA 3 2 1 UNIT MUST BE INSTALLED AFTER THE PRESSURE TANK CAUTION When Draining Chlorine Chlorine Can Bleach Clothing May Burn Eyes Skin PVC BALL VALVE DRAIN VALVE TO RELIEVE PRESSURE AND DRAIN UNIT 400 FEEDER PVC BALL VALVE U S PATENT NOS 5 053 ...

Page 7: ...ot add water to the unit or operation will be inhibited It may take a few pump cycles before chlorine is dispensed 6 Replace top No 4 and close drain valve 7 Tum on water NOTES If unit is opened after pressurization it is neces sary to drain fluid to the bottom of cap No 7 before repressurizing or operation will be inhib ited If unit is used for odor removal do not refill until odor returns to min...

Page 8: ... a smaller tank such as a 20 gallon tank cut the chlorine output by one half The Model 400 feeder will output the same amount of chemical for each pump cycle and a smaller tank is delivering less water on each pump cycle increasing the chemical concentration High odor and or Unit appears not to be dispensing the proper amount of chemical 1 Unit needs chlorine or it is over filled Max 3 4 full 2 Wr...

Reviews: