Section A

 - IntelliClimate

 Growroom Controller 

 

The IntelliClimate is the most advanced and user-friendly growroom environment controller on 
the market.  It has a wide range of possible applications which will be discussed briefly in this 
section. To keep the user interface as simple as possible, only the readings and settings relevant 

to the selected features are displayed on the controller’s LCD and on 

IntelliGrow.  To add extra 

features, enter 

“C

onfigure

 menus on the controller or 

“Functions” on

 IntelliGrow.   

 

Functions 
 

The controller can operate in a number of modes ranging from a simple cycle-timed mode to a 
sophisticated system making optimal use of a range of attached equipment.  After installing the 
unit,  tell  the  IntelliClimate  what  you  have  connected 

by  entering  “Configure”  menus  on  the 

controller or “Functions” on

 IntelliGrow. Once the controller knows what you have attached to 

it, it will automatically select the most appropriate mode of operation. When the controller is 
supplied, it is pre-set as a simple fan cooled environment controller with CO

2

 injection disabled. 

 

Lighting 
 

The IntelliClimate can control two light banks.  It is a good idea to split your lights into two groups.  
Firstly, when using both banks together, it allows the controller to stagger the switch on times, 
so  the power  surge  from  the  first bank has  subsided by the  time  the  second bank  comes  on.  
Secondly, during the vegetative phase of growth, the lights are on for longer periods (18 hours) 
but  a  lower  intensity  may  be  used.  The  controller  has  the  ability  to  switch  on  one  bank  and 
alternate the banks each day. This ensures that the plants receive light from both sides.  If one 
bank is turned on and the light sensor detects a low light level, the controller assumes that the 
bank is out of action (bulb blown) and automatically switches on the other bank. If alarms are 
enabled, it will alert you to the fact that a light has failed. Similarly, if a power failure occurs, the 
controller  has  a  programmable  cool-down  delay  timer  before  bringing  the  lights  back  on  in 
stages.  This has a significant impact on lamp life. 
 
 
 

 

*On IntelliGrow 

 
For those using air cooled lights, fit the cooling fan to blow air through the light fittings rather 
than suck out the hot air. This way the fans run cooler and last longer

 
 
 

 

 
 

Summary of Contents for IntelliClimate

Page 1: ...rols fans air conditioners heaters dehumidifiers humidifiers CO2 injection extraction two light banks Additional sensor available for larger growing areas Extensive fail safe features Settings can be...

Page 2: ...IntelliGrow Section B2 Settings via IntelliClimate keypad Section C Controller Installation Section D Maintenance Section E Fault finding Section F Specification Section G Compliance Declaration Discl...

Page 3: ...done as the growroom sensors are supplied with a long 5m 15ft cable If required this can be replaced with a longer cable Data cable such as CAT5 computer network cable should be used in this situatio...

Page 4: ...ity 24 hours a day and enables you to manage multiple locations from the comfort of your office using a single sign on Automatically manage your environment settings set remote alarms and data log you...

Page 5: ...t is pre set as a simple fan cooled environment controller with CO2 injection disabled Lighting The IntelliClimate can control two light banks It is a good idea to split your lights into two groups Fi...

Page 6: ...w For simple systems that have CO2 injection but do not have air conditioning or dehumidification the controller will operate as a cycle timer system with three timed phases Phase 1 Fans on Phase 2 Fa...

Page 7: ...ep the temperature humidity and CO2 close to the set points In the advanced settings of IntelliGrow you will see switching offsets for each device This allows you to set the offset from the main set p...

Page 8: ...fails the system will automatically switch to cooling by fans Power Supply Outputs The outputs voltages are all dependent on the power supply adapter used The IntelliClimate is supplied with a 24VDC p...

Page 9: ...e LCD display has some information on it Navigate to the Overrides menu and Force ON each piece of equipment to confirm your wiring is correct Connect IntelliClimate to the cloud Connecting your Intel...

Page 10: ...elliGrow gateway software Confirm your IntelliClimate is connected to your PC via USB cable If you experience any issues please contact support autogrow com Here are the instructions to activate your...

Page 11: ...ical equipment 5 Check the time date on the controller Configuration General First select your temperature units date format and name your device You can also import export settings and save your curr...

Page 12: ...he switching offsets are also useful to avoid overshoots when a heater or CO2 is switched off The IntelliClimate has standard offsets as a default but after observing your growroom you can alter these...

Page 13: ...occur when the air conditioner is running to avoid expelling the cool air If you would like to allow for air change while the air conditioner is running please tick the box On IntelliGrow Setpoint ra...

Page 14: ...gets a light reading or login to IntelliGrow and change this setting For further assistance please contact support autogrow com On IntelliGrow Most growers will want to minimize wastage of CO2 so you...

Page 15: ...liGrow Fogging Fogging is an effective way to cool your room down while helping to control relative humidity You can choose to use fogging to cool your room when the humidity is low enough that foggin...

Page 16: ...ause suffocation CO2 injection override If you run out of CO2 gas and the CO2 level falls below 300ppm the system will revert to using the fans to bring in ambient CO2 Fan fail override If in fan mode...

Page 17: ...bled under the function s menu On IntelliGrow Enabling a function will allow the controller to automatically manage the equipment to maintain your set points All functions except CO2 can be forced on...

Page 18: ...tion to IntelliGrow it will continue with the current set points until it is reconnected to the cloud Once you have entered your schedule you can save it to your local computer to be used again in the...

Page 19: ...ose your readings peripherals and targets If two of the colors are too similar click on the color box to change the color of the line You can save these settings to your local computer for future use...

Page 20: ...rt the data into a csv file Alarm Settings and Targets Set points are user defined You can set your desired temperature humidity CO2 to maintain an ideal growing environment The IntelliClimate will le...

Page 21: ...oints You can set the target to a desired value and it will force the setting one time and then revert back to original set point On IntelliGrow RH Relative Humidity You can set your minimum and maxim...

Page 22: ...growroom If the CO2 goes above or below it will trigger an alarm sending you a text and or email alert This feature can be enabled or disabled CO2 targets are continually adjusting to meet the demand...

Page 23: ...hrough the menus and when in a screen which allows you to edit a numeric value they are used for increasing or decreasing the values They are also used to select between different options On first pre...

Page 24: ...he wall If using the dry wall plaster board anchors use the longer screws supplied If fixing to a plywood back board use the shorter screws The low voltage power from the adapter is connected to the t...

Page 25: ...utogrow Systems Ltd 25 Connection to EnviroSensor A single cable is run from the IntelliClimate to the first enviro sensor which loops from the first enviro sensor to the second sensor if fitted Power...

Page 26: ...d EnviroSensor set to 2 Relay Boxes To drive mains powered equipment the 24V DC outputs must be connected to relays or contactors that have 24V DC coils We normally supply twin relay boxes that provid...

Page 27: ...Ver 6 0 IntelliClimate Installation Guide 21 August 2020 Copyright 2020 Autogrow Systems Ltd 27 Example connection of a relay box to operate Light1 and Fan1...

Page 28: ...isplayed on the screen The normal percentage is 100 If this ever needs to be set below 50 or above 150 this may indicate some deterioration of the sensor In this case first try the hard calibration be...

Page 29: ...ault first Inspect all wiring and ensure all wires are well insulated right to the point where they enter the terminal block Then replace the fuse with a genuine 4A fuse DO NOT ATTACH WIRE OR ALUMINIU...

Page 30: ...nsor and check that there is a green power light and a flashing red communications light System not showing CO2 readings Confirm there is power to the EnviroSensor by visually checking to see the inte...

Page 31: ...LED lights will read low by nature so place the sensor as close to the fixture as possible CO2 not injecting or CO2 active target displaying 0ppm Confirm your light readings are over the factory defa...

Page 32: ...ter RH resolution 2 and accuracy Temperature resolution and accuracy 0 5 C 32 9 F Temperature sensor range 0 50 C 32 125 F Operating temperature range 0 50 C 32 125 F not in direct sunlight CO2 resolu...

Page 33: ...chase Get the most out of your IntelliDose or IntelliClimate control systems with IntelliGrow IntelliGrow is a cloud based solution allowing you to access set monitor and manage your growing operation...

Page 34: ...nsor temperature humidity light CO2 1 x EnviroSensor temperature humidity light CO2 1 x 3m USB cable 1 x 3m USB cable 1 x Mounting hardware 1 x Mounting hardware 1 x Instruction manual 1 x Instruction...

Page 35: ...use harmful interference which the user will be required to correct the interference at his own expense The end user of this product should be aware that any changes or modifications made to this equi...

Reviews: