System not showing Light readings
-
The light sensor is on the top of the EnviroSensor, with the louvers pointed
down.
-
Make sure this sensor is under your lights, not upside down or mounted above
the lights.
-
LED lights will read low by nature, so place the sensor as close to the fixture as
possible.
•
CO
2
not injecting or CO2 active target displaying 0ppm
-
Confirm your light readings are over the factory default of 10 w/m2.
-
Confirm the system is in Day mode.
-
You must have at least one light bank enabled for CO2 to function
(even if a light is not connected)
-
By default, CO2 will not inject if Fan 1 is running. You can tick this box on
IntelliGrow to allow CO2 to inject while Fan 1 is running:
*On IntelliGrow