Ver 6.0 IntelliClimate Installation Guide (21 August 2020)
Copyright©2020 Autogrow Systems Ltd
32
Section F
- Specification
IntelliClimate
•
9 outputs 24VDC
•
Ratings of individual outputs are 3Amps but the total draw from all 9 outputs must
not exceed the rating of the supply adapter
•
RH resolution ± 2% and accuracy
•
Temperature resolution and accuracy 0.5°C/32.9°F
•
Temperature sensor range 0-50°C/32-125°F
•
Operating temperature range 0-50°C/32-125°F (not in direct sunlight)
•
CO
2
resolution and accuracy 50ppm
•
Power source
–
120V/240V into 24VDC plug pack (supplied)
•
Outputs will have the same voltage as the supplied voltage from the power pack
•
Supplied with 3m USB cable
Twin Relay Boxes
•
USA 110V 15A total draw
•
UK 240V 13A total draw
•
AUS/NZ 240V 10A total draw