Autogrow IntelliClimate Installation And User Manual Download Page 14

 

 

 

 
 

Ver 6.0 IntelliClimate Installation Guide (21 August 2020)

                        

Copyright©2020 Autogrow Systems Ltd 

14

 

 

 

 
CO

2

 rules 

 

CO

2

 injection is allowed when not venting.  You can choose to allow CO

2

 to inject when the 

Fan 1 is running.  This is useful if your Fan 1 is an HAF (air flow) fan. If your Fan 1 is an 
exhaust  fan,  tick  the  box  to  allow  the  IntelliClimate  to  reduce  CO

2

  injection  to  avoid 

wastage. 
 
 
 
 
 
  

 

If  your  light  levels  are  below  this  number,  your  CO

2

  will  not  inject.    Please  adjust  your 

EnviroSensor so it gets a light reading or login to IntelliGrow and change this setting. For 
further assistance, please contact 

[email protected]

 

 

 
 
 
 
 
 
 

 

*On IntelliGrow 

Most growers will want to minimize wastage of CO

2

, so you have a few options to choose 

from.  You can choose to allow the temperature set points to rise or fall to cycle CO

2

 most 

efficiently.   

 
 
 
 
 
 
 
 

*On IntelliGrow 

If  it  is  hot  and  the  room  is  frequently  venting,  you  can  reduce  CO

2

  injections.    You  can 

override these settings and control your CO

2

 by setting inject, wait and vent times to work 

for your specific growroom.  
 
 
 
 
 
 

*On IntelliGrow 

IMPORTANT:

 The IntelliClimate has a factory default to only allow CO

2

 injection when 

the light readings are above 10w/m2 

Summary of Contents for IntelliClimate

Page 1: ...rols fans air conditioners heaters dehumidifiers humidifiers CO2 injection extraction two light banks Additional sensor available for larger growing areas Extensive fail safe features Settings can be...

Page 2: ...IntelliGrow Section B2 Settings via IntelliClimate keypad Section C Controller Installation Section D Maintenance Section E Fault finding Section F Specification Section G Compliance Declaration Discl...

Page 3: ...done as the growroom sensors are supplied with a long 5m 15ft cable If required this can be replaced with a longer cable Data cable such as CAT5 computer network cable should be used in this situatio...

Page 4: ...ity 24 hours a day and enables you to manage multiple locations from the comfort of your office using a single sign on Automatically manage your environment settings set remote alarms and data log you...

Page 5: ...t is pre set as a simple fan cooled environment controller with CO2 injection disabled Lighting The IntelliClimate can control two light banks It is a good idea to split your lights into two groups Fi...

Page 6: ...w For simple systems that have CO2 injection but do not have air conditioning or dehumidification the controller will operate as a cycle timer system with three timed phases Phase 1 Fans on Phase 2 Fa...

Page 7: ...ep the temperature humidity and CO2 close to the set points In the advanced settings of IntelliGrow you will see switching offsets for each device This allows you to set the offset from the main set p...

Page 8: ...fails the system will automatically switch to cooling by fans Power Supply Outputs The outputs voltages are all dependent on the power supply adapter used The IntelliClimate is supplied with a 24VDC p...

Page 9: ...e LCD display has some information on it Navigate to the Overrides menu and Force ON each piece of equipment to confirm your wiring is correct Connect IntelliClimate to the cloud Connecting your Intel...

Page 10: ...elliGrow gateway software Confirm your IntelliClimate is connected to your PC via USB cable If you experience any issues please contact support autogrow com Here are the instructions to activate your...

Page 11: ...ical equipment 5 Check the time date on the controller Configuration General First select your temperature units date format and name your device You can also import export settings and save your curr...

Page 12: ...he switching offsets are also useful to avoid overshoots when a heater or CO2 is switched off The IntelliClimate has standard offsets as a default but after observing your growroom you can alter these...

Page 13: ...occur when the air conditioner is running to avoid expelling the cool air If you would like to allow for air change while the air conditioner is running please tick the box On IntelliGrow Setpoint ra...

Page 14: ...gets a light reading or login to IntelliGrow and change this setting For further assistance please contact support autogrow com On IntelliGrow Most growers will want to minimize wastage of CO2 so you...

Page 15: ...liGrow Fogging Fogging is an effective way to cool your room down while helping to control relative humidity You can choose to use fogging to cool your room when the humidity is low enough that foggin...

Page 16: ...ause suffocation CO2 injection override If you run out of CO2 gas and the CO2 level falls below 300ppm the system will revert to using the fans to bring in ambient CO2 Fan fail override If in fan mode...

Page 17: ...bled under the function s menu On IntelliGrow Enabling a function will allow the controller to automatically manage the equipment to maintain your set points All functions except CO2 can be forced on...

Page 18: ...tion to IntelliGrow it will continue with the current set points until it is reconnected to the cloud Once you have entered your schedule you can save it to your local computer to be used again in the...

Page 19: ...ose your readings peripherals and targets If two of the colors are too similar click on the color box to change the color of the line You can save these settings to your local computer for future use...

Page 20: ...rt the data into a csv file Alarm Settings and Targets Set points are user defined You can set your desired temperature humidity CO2 to maintain an ideal growing environment The IntelliClimate will le...

Page 21: ...oints You can set the target to a desired value and it will force the setting one time and then revert back to original set point On IntelliGrow RH Relative Humidity You can set your minimum and maxim...

Page 22: ...growroom If the CO2 goes above or below it will trigger an alarm sending you a text and or email alert This feature can be enabled or disabled CO2 targets are continually adjusting to meet the demand...

Page 23: ...hrough the menus and when in a screen which allows you to edit a numeric value they are used for increasing or decreasing the values They are also used to select between different options On first pre...

Page 24: ...he wall If using the dry wall plaster board anchors use the longer screws supplied If fixing to a plywood back board use the shorter screws The low voltage power from the adapter is connected to the t...

Page 25: ...utogrow Systems Ltd 25 Connection to EnviroSensor A single cable is run from the IntelliClimate to the first enviro sensor which loops from the first enviro sensor to the second sensor if fitted Power...

Page 26: ...d EnviroSensor set to 2 Relay Boxes To drive mains powered equipment the 24V DC outputs must be connected to relays or contactors that have 24V DC coils We normally supply twin relay boxes that provid...

Page 27: ...Ver 6 0 IntelliClimate Installation Guide 21 August 2020 Copyright 2020 Autogrow Systems Ltd 27 Example connection of a relay box to operate Light1 and Fan1...

Page 28: ...isplayed on the screen The normal percentage is 100 If this ever needs to be set below 50 or above 150 this may indicate some deterioration of the sensor In this case first try the hard calibration be...

Page 29: ...ault first Inspect all wiring and ensure all wires are well insulated right to the point where they enter the terminal block Then replace the fuse with a genuine 4A fuse DO NOT ATTACH WIRE OR ALUMINIU...

Page 30: ...nsor and check that there is a green power light and a flashing red communications light System not showing CO2 readings Confirm there is power to the EnviroSensor by visually checking to see the inte...

Page 31: ...LED lights will read low by nature so place the sensor as close to the fixture as possible CO2 not injecting or CO2 active target displaying 0ppm Confirm your light readings are over the factory defa...

Page 32: ...ter RH resolution 2 and accuracy Temperature resolution and accuracy 0 5 C 32 9 F Temperature sensor range 0 50 C 32 125 F Operating temperature range 0 50 C 32 125 F not in direct sunlight CO2 resolu...

Page 33: ...chase Get the most out of your IntelliDose or IntelliClimate control systems with IntelliGrow IntelliGrow is a cloud based solution allowing you to access set monitor and manage your growing operation...

Page 34: ...nsor temperature humidity light CO2 1 x EnviroSensor temperature humidity light CO2 1 x 3m USB cable 1 x 3m USB cable 1 x Mounting hardware 1 x Mounting hardware 1 x Instruction manual 1 x Instruction...

Page 35: ...use harmful interference which the user will be required to correct the interference at his own expense The end user of this product should be aware that any changes or modifications made to this equi...

Reviews: