T
RUMA
-U
LTRASTORE
This is a 10 l capacity liquid gas
storage heater.
Always read the manufacturers
operating instructions prior to
starting this appliance for the first
time and observe the 'important
operating notes'.
Filling the Truma-Ultrastore
with water
•
Check that the safety/drain valve
in the cold water intake is
closed: lever should be in the
horizontal, position (e). see drawing
•
Open hot tap in bathroom or
kitchen, with pre-selecting
mixing taps or single-lever
fittings set to ‘hot’.
•
Switch on power to water
pump (main switch or pump
switch).
•
Leave tap open to let air escape
while the water heater is filling.
The heater is full when water
flows out of the tap.
•
Residues of frozen water can
prevent filling if there is a frost.
The water heater can be
defrosted by switching on the
heater for a short period of
time (max. two minutes). Frozen
pipes can be defrosted by
heating the room.
Gas Operation
A - Rotary switch: ON - GAS
OPERATION.
B - Rotary switch: OFF
C - Rotary knob for temperature
selection (illuminated by green
light ‘operation’).
D - Red indicator lamp ‘FAILURE’
•
Remove cowl cover.
•
Open gas cylinder and quick-
acting valve in gas supply line.
•
Select required water
temperature at rotary knob (c)
in-finitely variable from approx
30ºC to 70ºC.
•
Switch on water heater at the
rotary switch (a) on the control
panel. Green ‘operation’ light
will illuminate.
•
If there is air in the gas supply
line, it may take up to a minute
before the gas is available for
combustion. If the appliance
switches to ‘Failure’ during this
period, switch off the appliance-
wait 5 minutes - then switch on again.
11.WATER: APPLIANCES