7-20
CONNECTION OF SERVICES
5.2 Common Fault Table
Fault
Possible Cause
Proposed Fix
No 230 volt
Connecting lead between
Check and connect lead as per 5.1C.
output from
the site and Leisure
Check also input connector at the base of the EC155PSU.
PSU.
Vehicle not connected.
RCD switched off.
Reset RCD as per 5.1D.
RCD not operating
Check supply polarity; if the RCD continues to fail contact your
correctly.
dealer, as there is probably an equipment or wiring fault.
MCB switched off.
Reset MCB by switching OFF (down position) then back ON (up
position), if the MCB continues to fail contact your dealer, as there is
probably an equipment or wiring fault.
No or deficient supply
Contact site warden for assistance.
from site.
Other fault.
Contact your dealer.
Control Panel
Control Panel has no display.
Check batteries & fuses, turn EC155PSU charger switch on, and
Problems
ensure mains supply is connected.
Check control panel connecting lead at EC155PSU and behind
Control Panel.
Contact your Dealer.
12V Power turns off.
Battery save feature has operated to protect the vehicle battery and or
the Leisure battery. See 3.4C.
Engine has been started, all equipment has been disconnected to meet
EMC requirements. See 4.3.
Control Panel display
Observe control panel handling instructions.
corrupt/erratic function.
Control panel software may have crashed. Reboot control panel by
turning off the EC155PSU charger switch and removing fuses 9 & 10
at the EC155PSU (2x20A fuses for leisure and vehicle batteries).
Wait 30 seconds then replace the fuses and turn the charger switch on.
(Alternatively, remove the bezel at the control panel by pulling down
in the centre of the bottom, unplug the control panel multi-way
connector, wait 30 seconds, then plug back in and reassemble.
No 12 Volt Output
No 230V supply.
Check all above.
from PSU
Charger not switched on.
Switch charger switch on (I) position, switch will illuminate.
Battery not connected and/or
Install charged battery as per 3.4.
charged.
Power switch on control
Turn power on at control panel.
panel not switched to ON.
Battery flat/Battery fuse
Recharge battery, check fuses, check charging voltage is present at
blown.
battery.
Fuse blown.
Check all fuses are intact and the correct value fuse is installed as
per fuse table.
Equipment switched off/
Check equipment is switched on and connected to the 12V supply.
unplugged.
PSU overheated/auto
Reduce load on system. Allow PSU to cool down. PSU will
shutdown operated.
automatically restart when cool. See section 3.
Other fault.
Contact your dealer.
Pump not working
Fuse blown.
Replace fuse.
Pump turned off.
Turn pump on by pressing the pump button at the EC155 control panel
(tap symbol).
Summary of Contents for Topaz
Page 6: ...1 4 ...
Page 10: ...2 4 MOTORHOME CODE ...
Page 16: ...5 2 ARRIVAL AT SITE ...
Page 24: ...6 8 SAFETY SECURITY ...
Page 46: ...7 22 CONNECTION OF SERVICES 12V 230V WIRING DIAGRAM ...
Page 73: ...9 23 FITTED EQUIPMENT 1 2 4 3 5 6 ...
Page 74: ...9 24 FITTED EQUIPMENT 7 8 10 9 11 12 ...
Page 78: ...9 28 FITTED EQUIPMENT ARRANGEMENT OF EQUIPMENT TOPAZ ...
Page 82: ...9 32 FITTED EQUIPMENT NORMAL SEATING ASSEMBLY TOPAZ ...
Page 83: ...9 33 FITTED EQUIPMENT DOUBLE BED ASSEMBLY TOPAZ ...
Page 84: ...9 34 FITTED EQUIPMENT SINGLE BED ASSEMBLY TOPAZ ...
Page 106: ...12 10 SERVICE DETAILS ...
Page 108: ...13 2 NOTES Designed and Printed by Preset Graphics Tel 01332 549278 MY 2016 Ref 21465 ...