background image

RESISTANCE MEASUREMENT 

1. 

Set the rotary switch to 

Ω. 

2. 

Insert the test leads into the input jack.

3. 

Connect the test probes of the test leads to the two ends 

of the resistor or circuit to be measured.

4. 

Read the measured value from the LCD.

CONTINUITY TEST 

WARNING:

    Before taking any in-circuit resistance 

measurement, remove power from the circuit being tested and 

discharge all the capacitors.

1. 

Turn the rotary switch to 

Ω

 position and move the sliding 

switch to AC position.

2. 

lnsert the test leads into the input jack.

3. 

Connect the test probes of the test leads to the 

two 

ends 

of the resistor or circuit to be measured.

4. 

Read the measured value from the LCD.

5. 

lf the resistance is lower than 10 

Ω

, a beeping sound 

will be 

heard.

CHARGING SYSTEM TESTS

The following section shows what you can do 

with the DM-46 in testing your charging system

State of Charge

1. 

Select DC Volts on the DM-46.

2. 

Place the Volt leads to the red (+) positive and black (-) battery 

terminals.

3. 

If the Volts are less than 12.5 Volts the battery needs charging

.

Amp Draw Check

4. 

Turn off ignition and all accessories.

5. 

Select DC 40 Amps on the DM-46.

6. 

Zero the DM-46 by pressing the yellow button.

7. 

Clamp the DM-46 around the positive (+) battery cable . Make 

sure it is clamped around all wires. 

8. 

If the display is above 2 Amps there is probably a draw upon 

the battery by the electrical system. This will drain the battery. 

Isolate and follow a suspected circuit and repeat reading until 

the problem is found. Consider a negligible drain with an on 

board computer.

12

9

Summary of Contents for DM-46

Page 1: ...The DM 46 is the auto industry s answer to pocket portability in a professionally accurate meter 2650 1910 77 11 9 16 Auto Meter Products Inc 413 West Elm Street Sycamore IL 60178 Service 815 899 0801 Toll Free 866 883 TEST 8378 www autometer com test T est Equipment 20 1 ...

Page 2: ...y claims to the manufacturer s service department must be transportation prepaid and accompanied with dated proof of purchase This warranty applies only to the original purchaser and is non transferable Shipper damage incurred during return shipments is not covered under this warranty It is the responsibility of the shipper the customer returning the Test Equipment to package the tester properly t...

Page 3: ...ry I CAT I Equipment for connection to circuits in which measures are taken to limit the transient overvoltages to an appropriate low lever Overvoltage Category II CAT II Energy consuming equipment to be supplied from the fixed installation Overvoltage Category III CAT III Equipment in fixed installations BATTERY REPLACEMENT 1 Turn the power off and remove the test leads from the clamp meter 2 Rem...

Page 4: ...easurement Press once minimum value shall be display and updated Press again maximum value shall be displayed and updated Zero function will be disabled if MAX MIN is enabled This button is not available in Duty Hz Continuity Diode or Capacitance function SPECIFICATIONS CONTINUED 4 17 TEMPERATURE K Type Thermal Couple w Adapter C or F Range Resolution Accuracy Overload Protection 40 0 C 0 1 C 2 0 ...

Page 5: ... to the actual reading Each segment represents one count 13 MAX or MIN is displayed on the LCD when the MIN MAX button is pressed 14 Continuity Symbol If continuity function is selected this symbol shall appear on LCD 15 Units are displayed on the LCD when a function is selected The corresponding symbols are V A Ω and Hz 16 V Ω Hz Capacitance Temperature input Terminal This terminal is used as inp...

Page 6: ...e jaw and fully enclose the conducting wire to be measured Be sure there is no air gap between the two half jaws 3 Read the measured value from the LCD SPECIFICATIONS Conductor Size 23mm max approx Battery Type two 1 5V AA Display 3 3 4 LCD with 40 seg bar graph Range Selection manual Overload Indication OL Power Consumption 10mA approx Low battery Indication Sampling Time 3 times sec display 30 t...

Page 7: ...s proper procedure to disable ignition if needed Improper methods could cause damage to vehicles that are computer controlled 2 Determine the manufactures Starter Draw specifications If not available use the following chart as a guide 3 Select DC 200 Amp and zero the DM 46 by pressing the yellow button 4 Press the MAX MIN button twice and make sure the display reads HOLD MAX 5 Clamp the DM 46 arou...

Page 8: ...from 12 8 to 15 Volts DC If the reading is low the alternator is not charging If the reading is high the alternator is over charging and could damage the battery 7 Switch the DM 46 to DC 200 Amps 8 Clamp the DM 46 around the positive alternator conductor leading to the positive terminal of the battery See illustration above 9 Make sure the small arrow inside the clamp is pointing in the direction ...

Page 9: ... the resistance is lower than 10 Ω a beeping sound will be heard CHARGING SYSTEM TESTS The following section shows what you can do with the DM 46 in testing your charging system State of Charge 1 Select DC Volts on the DM 46 2 Place the Volt leads to the red positive and black battery terminals 3 If the Volts are less than 12 5 Volts the battery needs charging Amp Draw Check 4 Turn off ignition an...

Page 10: ...rmal mode But this function is disabled if MAX MIN function is enabled Please watch for symbol displayed on LCD Press the HOLD button and the reading will be held on the LCD FINDING THE MAX MIN VALUE Press the MAX MIN button to enable the maximum and minimum values to be recorded and updated during measurement Push the button once the maximum value will be displayed and updated The LCD display tog...