FEATURES

 

10mA high resolution on 40A DC/AC range.

 

Temperature (Degrees C or F)

 

and Capacitance

 

One touch zero for DCA adjustment.

 

Auto-range for V, A, 

Ω

, F, and temperature

 

Frequency (Hz).

 

23 mm diameter jaw.

 

Fast bar graph display (30 times/sec.) for transient observation.

 

Continuity and frequency measurements.

 

Max/Min and Data Hold functions.

 

600V overload protection for ohm measurement.

 

Ideal for working in crowded switch box or cable areas.

CONTROLS AND FUNCTIONS

1. 

Transformer Jaw

 is used to pick up current signal. It measures DC/AC 

current. The jaw must enclose the conducting wire.

2. 

Transformer Trigger

 is used to open the jaw.

3. 

Function Selector Switch 

is used to select the function such as DCA, 

ACA, DCV, ACV, Hz, Ohm and Continuity.

4. 

AC/DC 

select switch. This is used to select AC or DC voltage or 

current, Hz or Duty, Ohm or Continuity, Capacitance or Diode, °F or °C.

5. 

Data Hold Button 

holds the LCD reading when pushed

Press again 

to release it. This button is not available in continuity or diode function.

6. 

Max/Min Hold Button.

 This button is used to enable the maximum 

or minimum value to be displayed and updated during measurement. 

Press once, minimum value shall be display and updated. Press again, 

maximum value shall be displayed and updated. Zero  function will be 

disabled if MAX/MIN is enabled. This button is not available in Duty, 

Hz, Continuity, Diode or Capacitance function. 

SPECIFICATIONS CONTINUED

4

17

TEMPERATURE (K Type Thermal Couple w/ Adapter, °C or °F):

Range

Resolution

Accuracy

Overload Protection

-40-0°C

0.1 °C

2.0%   2 °C

AC 600V

0-400°C

0.1 °C

0.5%   2°C

AC 600V

400-1000°C

1°C

0.5%   2 °C

AC 600V

-40-0°F

0.1°F

2.0%   4°F

AC 600V

0-400°F

0.1°F

0.5%   4°F

AC 600V

400-1800°F

1°F

0.5%   4°F

AC 600V

RESISTANCE (

):(open voltage 0.4V)

Range

Resolution

Accuracy

Overload Protection

400 

Ω

0.1 

Ω

1.5%   2dgts

AC 600V

4K 

Ω

Ω

1.5%   2dgts

AC 600V

40K 

Ω

10 

Ω

1.5%  2dgts

AC 600V

400K 

Ω

100 

Ω

1.5%  2dgts

AC 600V

4M 

Ω

1K 

Ω

1.5%  2dgts

AC 600V

40M 

Ω

10K 

Ω

1.5%  2dgts

AC 600V

CONTINUITY (open voltage 0.4V, Overload Protection Ac600V)

Range

Resolution

Accuracy

Beeping

40-400 

Ω

0.1 

Ω

1.0%   2dgts

<10.0 

Ω (approx)

FREQUENCY: (Auto, sensitivity selected by pressing RANGE Button)

Range 

(Hz)

Resolution 

(Hz)

Accuracy

Sensitivity

Overload 

Protection

1-100K

0.001-100Hz

0.5%   2dgts

5V

AC 600V

+-

+-

+-

+-

+-

+-

+-

+-

+-

+-

+-

+-

+-

+-

+-

+-

+-

+-

+-

+-

+-

+-

+-

+-

+-

+-

+-

+-

CAPACITANCE: 

Range

Resolution

Accuracy

Overload Protection

40nF

10pF

5.0%    0.2nF

AC 600V

400nF

0.1nF

3.0%    0.2nF

AC 600V

4

μ

1nF

3.0%    0.02

μ

F

AC 600V

40

μ

F

10nF

3.0%    0.02

μ

F

AC 600V

400

μ

F

100nF

3.0%    0.02

μ

F

AC 600V

+-

+-

+-

+-

+-

+-

+-

+-

+-

+-

Summary of Contents for DM-46

Page 1: ...The DM 46 is the auto industry s answer to pocket portability in a professionally accurate meter 2650 1910 77 11 9 16 Auto Meter Products Inc 413 West Elm Street Sycamore IL 60178 Service 815 899 0801 Toll Free 866 883 TEST 8378 www autometer com test T est Equipment 20 1 ...

Page 2: ...y claims to the manufacturer s service department must be transportation prepaid and accompanied with dated proof of purchase This warranty applies only to the original purchaser and is non transferable Shipper damage incurred during return shipments is not covered under this warranty It is the responsibility of the shipper the customer returning the Test Equipment to package the tester properly t...

Page 3: ...ry I CAT I Equipment for connection to circuits in which measures are taken to limit the transient overvoltages to an appropriate low lever Overvoltage Category II CAT II Energy consuming equipment to be supplied from the fixed installation Overvoltage Category III CAT III Equipment in fixed installations BATTERY REPLACEMENT 1 Turn the power off and remove the test leads from the clamp meter 2 Rem...

Page 4: ...easurement Press once minimum value shall be display and updated Press again maximum value shall be displayed and updated Zero function will be disabled if MAX MIN is enabled This button is not available in Duty Hz Continuity Diode or Capacitance function SPECIFICATIONS CONTINUED 4 17 TEMPERATURE K Type Thermal Couple w Adapter C or F Range Resolution Accuracy Overload Protection 40 0 C 0 1 C 2 0 ...

Page 5: ... to the actual reading Each segment represents one count 13 MAX or MIN is displayed on the LCD when the MIN MAX button is pressed 14 Continuity Symbol If continuity function is selected this symbol shall appear on LCD 15 Units are displayed on the LCD when a function is selected The corresponding symbols are V A Ω and Hz 16 V Ω Hz Capacitance Temperature input Terminal This terminal is used as inp...

Page 6: ...e jaw and fully enclose the conducting wire to be measured Be sure there is no air gap between the two half jaws 3 Read the measured value from the LCD SPECIFICATIONS Conductor Size 23mm max approx Battery Type two 1 5V AA Display 3 3 4 LCD with 40 seg bar graph Range Selection manual Overload Indication OL Power Consumption 10mA approx Low battery Indication Sampling Time 3 times sec display 30 t...

Page 7: ...s proper procedure to disable ignition if needed Improper methods could cause damage to vehicles that are computer controlled 2 Determine the manufactures Starter Draw specifications If not available use the following chart as a guide 3 Select DC 200 Amp and zero the DM 46 by pressing the yellow button 4 Press the MAX MIN button twice and make sure the display reads HOLD MAX 5 Clamp the DM 46 arou...

Page 8: ...from 12 8 to 15 Volts DC If the reading is low the alternator is not charging If the reading is high the alternator is over charging and could damage the battery 7 Switch the DM 46 to DC 200 Amps 8 Clamp the DM 46 around the positive alternator conductor leading to the positive terminal of the battery See illustration above 9 Make sure the small arrow inside the clamp is pointing in the direction ...

Page 9: ... the resistance is lower than 10 Ω a beeping sound will be heard CHARGING SYSTEM TESTS The following section shows what you can do with the DM 46 in testing your charging system State of Charge 1 Select DC Volts on the DM 46 2 Place the Volt leads to the red positive and black battery terminals 3 If the Volts are less than 12 5 Volts the battery needs charging Amp Draw Check 4 Turn off ignition an...

Page 10: ...rmal mode But this function is disabled if MAX MIN function is enabled Please watch for symbol displayed on LCD Press the HOLD button and the reading will be held on the LCD FINDING THE MAX MIN VALUE Press the MAX MIN button to enable the maximum and minimum values to be recorded and updated during measurement Push the button once the maximum value will be displayed and updated The LCD display tog...

Reviews: