1.
Set the rotary switch at 40A or 200A and move the
sliding switch to DC.
2.
Push the zero button to zero reading the Amp reading.
3.
Press the trigger to open the jaw and fully enclose the
conducting wire to be measured. Be sure there is no air
gap between the two half jaws.
4.
Read the measured value from the LCD.
DC/AC CURRENT MEASUREMENTS
WARNING:
Make sure that
all the test leads are disconnected
from the
meter’s terminals for current measurement.
DC CURRENT
AC CURRENT
1.
Set the rotary switch at 40A ~ or 200A ~, and move the
sliding switch to AC.
2.
Press the trigger to open the jaw and fully enclose the
conducting wire to be measured. Be sure there is no air
gap between the two half jaws.
3.
Read the measured value from the LCD.
SPECIFICATIONS
Conductor Size:
23mm max. (approx.)
Battery
Type:
two
1.5V
AA
Display
3 3/4 LCD with 40 seg. bar graph
Range Selection:
manual
Overload Indication:
OL
Power Consumption:
10mA (approx.)
Low battery Indication
Sampling Time:
3 times/sec. (display)
30
times/sec.
(bar
graph)
Auto-Power-Off
15 Minutes
Operating Temperature:
-10
o
C to 50
o
C
Operating Humidity:
less than 85% relative
Altitude:
up to 2000M
Storage Temperature
-20
o
C to 60
o
C
Storage Humidity
less than 75% relative
Dimension:
7.2” x 2.5” x 1.4”
Weight:
190g (battery included)
Accessories:
Adapter for Capacitance and
K-type
Thermal
Couple
Carrying bag
Instruction Manual