background image

BATTERY

18

MAINTENANCE 

IMPORTANT:  

  Both jaws of each clamp 

must firmly engage the 

battery terminal.  The 
copper jaw contains the 
smaller gauge wire that 
reads the voltage and 
the silver jaw contains 
the larger conducting 
wire that draws the 
load in each test.  Jaw 
insulation is necessary 
for accurate readings.  
Damaged clamps or 
loose wires will affect 
the readings.  Keep 
clamps clean and in 
good repair.   

CHECK OFTEN FOR LOOSE JAWS 

OR DAMAGED INTERNAL PLASTIC 

SHOULDER INSULATORS

 

BATTERY CLAMP REPLACEMENT 

Over time the battery clamps will need to be replaced if any of the 
following are indicated:  

  CCA values seem to be way off.  
  If there is continuity between the silver and copper jaw.  
  If there is excessive damage or corrosion to the cables or 

clamps.  

PROCEDURE

  Disconnect the back cover.  
  Disconnect the two small wires from the PCB.  
  Remove the large cables from the copper busses.    
  Carefully pull each wire through the grommets.  
  Reverse the procedure when installing new clamps.

  

Caution

:  With cables pointing down, make sure the red clamp 

wires are attached to the left buss and the black clamp is attached 
to the right buss.  Putting a little mineral spirits on the new cable 
ends will help with ease of insertion through the grommets.   

BATTERY REPLACEMENT 

When the LCD indicates a low internal battery remove the back cover 
and replace the battery with a 9 volt Alkaline battery.  

VOLT METER

Unusual problems with a battery and the need to localize loss of current 
can be determined with the manual volt reading.  

From the Other Menu select 

Volt Meter

.

Press (Y Enter) 

The following will be displayed.  

Note: If the car is running and 
the clamps are attached to the 
battery a high ripple (over 50.0 
mv) indicates bad diodes in the 
alternator

.  

SETUP

From the main menu select OTHER the ABOUT for the second menu.

Select the temperature in 
Fahrenheit or Centigrade.

Select the rating from JIS, 
DIN, IEC, EN, CA, MCA, CCA 
or NONE. If none is selected, 
each time a battery test is per-
formed the unit will prompt for 
the battery rating.

 REVIEW/PRINT 

>VOLT METER 

 SETUP      

 ABOUT

 

--VOLT METER--

VOLTS:  12.24V

RIPPLE  00.0mV 

 REVIEW/PRINT

 VOLT METER

>SETUP

 ABOUT

>SET TEMPERATURE 

 SCALE: F. 

 USE +/-. 

 ‘Y’ TO SELECT 

>DEFAULT BATTERY 

 RATING: CCA 

 USE +/-. 

 ‘Y’ TO SELECT 

Summary of Contents for BVA-200s

Page 1: ...ortability in a professionally accurate load tester and system analyzer Rev C Auto Meter Products Inc 350 West Center Street Pleasant Grove Utah 84062 Service 801 785 0051 ext 223 Toll Free 866 883 TE...

Page 2: ...WARRANTY 12 MONTHS FROM DATE OF PURCHASE CABLES 90 DAYS The manufacturer warrants to the consumer that this product will be free from defects in material or workmanship for a period of twelve 12 mont...

Page 3: ...ing Test Results 17 Voltmeter 18 Setup 18 PC Interface 19 Opening Windows 98 Hyper Terminal 19 Downloading Test Information 20 Capturing Information in Microsoft Excel 21 Warranty Information 23 Conta...

Page 4: ...greatly reduce battery life and affect battery performance Age of Battery If the date code on the battery indicates it is fairly old the failure may be caused by natural causes Overcharging Overcharg...

Page 5: ...Est Output DOWNLOAD TEST INFORMATION 3 PC Screen Menu If the BVA 200s is properly connected to your PC and the LCD shows CONNECT ANALYZER TO A PC the menu should automatically be displayed in Hyper Te...

Page 6: ...e in a name for your connection Select an icon for future identification Select OK Select the COM port number you have previously identified in step 1 Select OK and select the following from the pull...

Page 7: ...g down make sure the red clamp wires are attached to the left buss and the black clamp is attached to the right buss Putting a little mineral spirits on the new cable ends will help with ease of inser...

Page 8: ...er jaw CHECK CONNECTIONS will flash Make sure the Infrared Printer is properly set up After a test is made with the BVA 200s make sure the results are displayed on the LCD Point the BVA 200s in the di...

Page 9: ...t test will be displayed Press N Esc to select previous test Press Up or Down key to select the desired test The optional AC 15 printer An invisible infrared beam links the BVA 200s to the printer fro...

Page 10: ...cally a ripple above 50mV indicates a bad diode If the system has a strong battery the ripple will be lower than if the system has a weak battery NOTE 2 If the LCD reads LOW OUTPUT or EST OUTPUT it is...

Page 11: ...eck belt condition and tension Check all cables and connections Check the battery for corrosion and dirty terminals Does the battery have a low state of charge See section 2 and 3 Make sure all electr...

Page 12: ...ngine After a few seconds the test result will appear Compare draw reading with manufactures specifications If manufacturer s specifications are not available the chart below can be used as a general...

Reviews: