2317 Rev 1.1 (17NOV04)
AuthenTec Confidential Information
36
6.1.1.11 Measure
Frequency
(MEASFREQ)
(8Ah)
Reset
Value
D7
D6
D5
D4
D3
D2
D1
D0
Reserved
Reserved
Reserved
Reserved
Measure
Freq [2]
Measure
Freq [1]
Measure
Freq [0]
0
0
0
0
0
0
1
0
1
Measure Frequency
Sets the frequency of the excitation generator when in Detect mode. Out of range values default to the 2 MHz
setting.
001
125 KHz
010
250 KHz
011
500 KHz
100
1 MHz
101
2 MHz
For best results, the measurement frequency and column scan rate should be selected so that at least 16 cycles
of the measurement frequency occur during the integration time period (see column scan rate).