2317 Rev 1.1 (17NOV04)
AuthenTec Confidential Information
34
6.1.1.9
Column
Scan
Rate
(COLSCAN) (88h)
Reset
Value
D7
D6
D5
D4
D3
D2
D1
D0
Reserved
Reserved
Reserved
Column
Scan
Rate [3]
Column
Scan
Rate [2]
Column
Scan
Rate [1]
Column
Scan
Rate [0]
0
0
0
0
0
0
0
1
1
Column Scan Rate [3:0]
Sets the time used for scanning one column when using standard Analog Channel circuitry. Out of range
settings default to the 2048 us scan period. The time shown in the table for additional data is the time to send
the end of frame data (9 bytes authentication word and header plus 64 bytes register data) and assumes the
lowest valid baud rate. The Min Baud Rate shown is the lowest baud rate that can be used in gray scale mode
(non-packed) without causing scanning to pause. The pixel integration time can be calculated using the
equation:
Pixel integration time = Column Rate – 20us
Value Column
Rate
Image Time
0000 Reserved
0001 Reserved
0010 32
us Required
Value
for best
performance
0011 64
us
0100 128
us
0101 256
us
0110 512
us
0111 1024
us
1000 2048
us
1001 4096
us
1010 8192
us
1011 16384
us
1100 32768
us
1101 65536
us
111X 65536
us