2317 Rev 1.1 (17NOV04)
AuthenTec Confidential Information
31
6.1.1.5 Navigation Correlation Range (NAVCORRNGE)
(84h)
Reset
Value
D7
D6
D5
D4
D3
D2
D1
D0
Reserved
Nav.
Select [1]
Nav.
Select [0]
Nav.
Corr.
Range[3]
Nav.
Corr.
Range[2]
Nav.
Corr.
Range[1]
Nav.
Corr.
Range[0]
0
0
0
0
0
0
1
1
1
Nav. Select[1:0] – Selects mode for determining Up/Down versus Left/Right
00
If the number of excited pixels in the center column is greater than Register 0x85, then
Up/Down determination will be made, otherwise make Left/Right determination.
01
If excited pixels in the left, center, and right columns are greater than Register 0x85, then Up/Down
determination will be made, otherwise make Left/Right determination.
1X Reserved.
Nav. Corr. Range[3:0]
This register selects the shift range for correlation when in navigation mode and imaging mode for
determining shifts to peak correlation. This value limits the number of pixel shifts of the reference images
when correlating with the current center column of pixel data. When reference columns are shifted, the fill
data is ‘0’, which can in some circumstances cause errors in the correlation data. The default value in this
register should be acceptable for most finger data.
6.1.1.6 Navigation Finger Detect Threshold (NAVFDTHRSH) (85h)
Reset
Value
D7
D6
D5
D4
D3
D2
D1
D0
Reserved
Reserved
Nav. Fing.
Detect
Thresh[4]
Nav. Fing.
Detect
Thresh[3]
Nav. Fing.
Detect
Thresh[2]
Nav. Fing.
Detect
Thresh[1]
Nav. Fing.
Detect
Thresh[0]
0
0
0
0
0
0
0
1
0
Nav. Fing Detect Thresh[4:0]
Sets the threshold for image based finger detect in navigation mode. It is used to determine if there is a
sufficient amount of pixel data in the center column to do up/down direction determination vs. left/right
determination. See Register 0x84 for additional options.