2317 Rev 1.1 (17NOV04)
AuthenTec Confidential Information
27
6.1.1.1
Control
Register
1
(CTRL1)
(80h)
Reset
Value
D7
D6
D5
D4
D3
D2
D1
D0
Reserved
Reserved
Reserved
Nav
Mode
Op
Enable
Scan
Reset
Master
Reset
0
0
0
0
0
0
0
0
0
Nav Mode
1
Device will operate in navigation mode, making the contents of register 9Bh valid.
0
Device is in imaging mode; contents of register 9Bh are invalid.
OP Enable
1 Imaging or Navigation Mode is enabled.
0 Forces idle mode. Clocking is disabled except when enabled by interface activity.
Scan Reset
1
Perform a scan reset. This stops any imaging scan currently in progress and restarts the scan sequencer at
recheck for finger present. If an image scan is not in progress, no action is performed. This bit is self-resetting
and will always read back as zero.
Master Reset
1
Perform a master reset (same as Power On Reset). This resets all registers to their initial values. Output
registers and buffer registers are loaded with reset values. This bit is self-resetting and will always read back
as zero. This reset does not affect GPIO register settings.
Headings in bold denote default state functionality