103
Compliance
FCC (EMC), CE (EMC and LVD), RoHS
Warranty
1 year
NOTE
Reduced to 20MS/s if channels A and B, or C and D, are enabled.
Screen Layout and Operations
The MaxiScope application works as a signal processing program that displays the
shape of electrical signals onscreen with a live graph showing voltage against time. The
grid on the screen shows divisions of voltage and time to enable measurements to be
made.
Units of voltage per division are shown down the side of the scope screen while units of
time per division are shown along the bottom. The graph is referred to as a waveform
and the scope repeatedly draws the trace across the screen from left to right.
Before performing the MaxiScope application, the MaxiScope Module must be
connected to the tablet. Apply appropriate probe accessories supplied with the
MaxiScope tool kit for use in various tests.
Figure 16-4
Sample MaxiScope Application Screen Layout
1. Top Toolbar
– used for configurations of various settings and operations of the
scope.
2. Functional Buttons on the top
– used for configurations of channel activation,
measurement scale and trigger settings.
3. Measurement Grid
–
displays measurements of voltage against time.
4. Functional Buttons
at the bottom
– used for configurations of trigger, time base,
and measurement parameter display settings.