en/TA-11-ALM-6040/10040FL
pag.: 33
USER /
INSTALATION
MANUAL
4-POST HD
ISSUED 26-05-04
A L M - 6 0 4 0 F L
A L M - 1 0 0 4 0 F L
AUTEC Hefbruggen bv
Industrieterrein IJsselveld, Vlasakker 11, 3417 XT MONTFOORT, The Netherlands
Tel: +31 348 477000 Fax: +31 348 475104 Internet: www.autec.nl - E-mail: [email protected]
9 . 3
G e a r b o x e s
Check oil level every six months by removing the three screws
(17)
which fix the flaps
(18)
above the cross
pieces and unscrew the level plugs
(42)
with a 6 mm hexagonal bar key. Check level and use a syringe to top
up with oil if necessary through the holes of the plugs
(42)
. To
CHANGE THE OIL
(every 1,000 strokes or once
a year) remove the flaps also from the bottom of the cross pieces to reach the discharge plugs.
9 . 4
A n g u l a r t r a n s m i s s i o n s
Every six months remove level plugs
(43)
above the footboard
(7)
, using a 6 mm hexagonal bar key. Check the
oil level and top up if necessary, taking care not to exceed the maximum level. Use a syringe to add or remove
oil through the hole of the plug
(43)
.
9 . 5
C h e c k i n g t h e w e a r o n t h e l o a d - b e a r i n g s u p p o r t s c r e w s
Every six months raise the lift with footboards to about 1 metre from the ground, remove the flaps from the bot-
tom of the cross pieces, remove the plastic tubing inserted in the outlet of each cap and pull the cap downwards.
fig. 26
fig. 27