Remove the screws
(17)
fasten the flaps
(18)
and fill each container
(19)
with oil (about 50g.). Pull the lower
part of the flaps
(18)
outwards and put oil into the small containers at the bottom of the posts, upto the right
level
(20)
. Use SPARTAN EP 220-210St OIL at 40°C (ESSO), or similar.
Electrical circuit connections.
The minimum power required is 25 kW. Use the 10 mm
2
cable for the main power supply. Make sure that the
motor voltage is the same as the main; to change voltage from 220 to 380 Volts or vice versa, change the con-
nections of both the 4 motors and transformer
(fig. 6)
.
W A R N I N G :
check that wires and terminals are matched to the right numbers.
Connect the phase wires to terminals on the main switch and connect the yellow-green wire to the right termi-
nal. When connection is complete, connect to main and turn switch
(21)
to position 1.
fig. 15
M o t o r c o n n e c t i o n
T r a n s f o r m e r c o n n e c t i o n (
N.B. only shift wire W and U
)