background image

VISUALTECH SWITCHBOARD

 

 

 

 

 

User Guide

 

 

 

auta 

Queue 

   Settings 

   Configuration       

Main Menu 

  Navigate 

        OK  Accept 

 Exit                       

 

 

 

 

3. Menus 

 

In the stand by mode, if any of the keys 

OK

 or 

 is pressed, the screen will 

display the menu shown in Figure 5. Any option can be selected making use of the 
vertical arrows 

 

and the 

OK

 button

3

 
 
 
 
 
 
 
 

 

 

 

 

 

 

 

 

 

Figure 5.

 Main menu of the SB 

 
 

 

3.1.  Queue: 

 

 

The 

Queue menu

 can also be reached directly from the 

Stand by

 mode pressing the 

up key 

 

of the navigator.

 

 

 

This menu allows to navigate through the registers of the queue, and to perform a 
call to any of them, and pressing the 

OK

 button. In Figure 6 there is an example.

 

 

 

The registers in the 

Queue

 will remain stored in the database unless the Erase key 

(

) is pressed inside this menu, or the call is returned to the corresponding tenant.

 

 

 

The maximum size of the 

Queue

 is 25 registers. If more than 25 calls are stored in 

the 

Queue

, the newest calls will replace the oldest.

 

 

 

If there isn’t any call stored, the system will display the message 

Empty Queue. 

 

                                                 

3

 At the bottom of the screen there is always information about the different actions the user can execute. 

22

Summary of Contents for COMPACT VISUALTECH

Page 1: ...CENTRAL COMPACT INTEGRADA INTEGRATED GUARD UNIT CENTRAL HI 86 02 05 AUX 1 2 3 4 5 6 7 8 9 0 LLAMANDO A 120506 HI 219 12 16 COMPACT VISUALTECH...

Page 2: ...s 3 Conectar la central con el latiguillo al circuito del m dulo de conexi n 4 Colgar la central en la plancha fijada en la pared 1 Fix the bracket to the wall using supplied screws 2 Connect the wire...

Page 3: ...on a que ya dispon an de una central de conserjer a podr n actualizarse con modernos equipos de videoportero que operar n junto con la central VISUALTECH De esta forma ser posible incorporar video en...

Page 4: ...placa se pasar n directamente a las viviendas La conserjer a podr monitorizar la existencia de la llamada pero no podr escuchar ni interrumpir la conversaci n Si se llama a conserjer a desde placa con...

Page 5: ...n la acci n que se est realizando llamada conversaci n navegar por los men s etc La botonera vertical es la misma del monitor VISUALTECH y con funciones similares La descripci n de los 4 botones que...

Page 6: ...la Central es interior son v lidos c digos de hasta tres cifras desde el 1 al 254 Si la Central es exterior los c digos pueden ser de hasta cuatro cifras siendo los dos primeros 1 a 63 el c digo del...

Page 7: ...video en su monitor la pantalla quedar en blanco La llamada se indica por el parpadeo del led en verde En la central Se mostrar n los datos correspondientes del Tel fono Monitor y si la central es ext...

Page 8: ...a de la instalaci n Para ello una vez la central tiene comunicaci n con placa pulsar la tecla OK tendr asignada la funci n de Cambiar en ese momento y el sistema permitir incrementar o decrementar el...

Page 9: ...la llamada y realizar una consulta a otra vivienda OK b squeda Figura 4 Llamada desde la placa 14 al monitor 129 Llamada con c digo 0 Llamada a Central La llamada se tratar como cualquier otra con la...

Page 10: ...ras haber hablado con la placa de calle contacta con la vivienda En ese momento tanto central como vivienda tienen video directo desde la placa de calle pero audio s lo entre central y vivienda Si el...

Page 11: ...Las llamadas se almacenar n por orden de realizaci n y no se encolar n llamadas que ya tengan pendientes una llamada en la cola Si se superan las 25 llamadas en la cola las m s antiguas ser n elimina...

Page 12: ...te a las llamadas realizadas desde las placas de calle Estos modos de operaci n son Modo Est ndar La conserjer a recibe todas las llamadas de la placa de calle y si en 30 segundos no se atienden se pa...

Page 13: ...ra los timbrazos Los valores de estos ajustes se modifican mediante las teclas Si se pulsa la tecla OK se generar un timbrazo de muestra con los ajustes actuales de tipo y volumen Para salir de este m...

Page 14: ...que la central se instale junto con el SDL especial SDL VISUALTECH E Consultar con el servicio t cnico esta instalaci n Para salir del men pulsar la tecla 3 3 2 Cambio de clave Este men permite cambia...

Page 15: ...o installations which already had a switchboard may be upgraded with modern video equipment that will operate in conjunction with the VISUALTECH switchboard Thus it will be possible to incorporate vid...

Page 16: ...30 seconds they will be passed through automatically to the tenants Direct Mode All the incoming calls made from the panel will be automatically passed through to the tenants The SB won t be able to i...

Page 17: ...a bright blue light This led brings some important information since it lights in a different manner depending on the state the SB is of its working protocol The led states are Led Off the SB is in S...

Page 18: ...e key Exit is pressed at any moment the entry of numeric codes will be cancelled Navigating through the queue From the stand by mode if the key is pressed the system grants access directly to the Queu...

Page 19: ...Telephone Monitor If the guard porter answer the call or rejects it pressing the self starting button of the SB the call will not be stored in the Queue1 otherwise the register corresponding to that...

Page 20: ...el with any monitor in the installation For that once he has the communication with the panel established if the OK Change button is pressed the system will allow the user to navigate using or enterin...

Page 21: ...h the code 0 Call to the guard porter The call will be handled like any other except it will not be passing to directly the code 0 is forbidden for monitors telephones It will be necessary to redirect...

Page 22: ...st the tenant whether he wants to accept the call or not Both of them the tenant and the guard porter will be watching the same video picture from the outdoor panel If the tenant decides to accept the...

Page 23: ...is menu allows to navigate through the registers of the queue and to perform a call to any of them and pressing the OK button In Figure 6 there is an example The registers in the Queue will remain sto...

Page 24: ...SDL 4 is the first of 23 calls queued 3 2 Settings From this menu you can make settings related to how the SB works according to user preferences See figure 7 Figure 7 Settigs menu auta Mode Ringtone...

Page 25: ...rent settings To exit from this menu choose the option Back and confirm with OK 3 2 3 Audio The parameters of audio input and output can be modified in a similar way that in the previous settings usin...

Page 26: ...exit from this menu press 3 3 3 Change Password This menu allows to change the password to access the Configuration menu The new password can be any combination from 1 to 9 digits It is recommended t...

Page 27: ...or Zx Installations with SDL The SB will be mounted on the external bus Zx CCI VISUALTECH VERDE Y BLANCO GREEN AND WHITE Vb VERDE GREEN Va Z NARANJA BLANCO NARANJA ORANGE WHITE ORANGE MARRON BLANCO MA...

Page 28: ...auta comunicaciones s l POL IND EL OLIVERAL CALLE C 46394 RIBARROJA DEL TURIA VALENCIA TFNO 34 96 164 30 20 FAX 34 96 166 52 86 E MAIL AUTA AUTA ES HTTP WWW AUTA ES...