YUNO-II user manual v1.1
25
Status Command
You can send below command sequence to COM to read drawer status.
Read Drawer Status
Read Status
0x1D
0x72
0x02
You can read drawer status after “
Read Drawer Status
” command.
Drawer Status
0x01
Drawer Opened
0x00
Drawer Closed
ASB Command (Automatic Status Back)
If ASB mode is activated, the PUH will report status if drawer status has changed.
You can use command to enable or disable this function.
The ASB is disabled by default when PUH power on. You need to enable ASB after
each time power on.
Enable ASB function
Enable ASB
0x1D
0x61
0x01
Disable ASB function
Enable ASB
0x1D
0x61
0x00
ASB Message - Status Report
The ASB message are always 4 bytes with some fixed bits which can be used to
identify the message as an ASB message. Bit 2 of the first byte signals the
drawer state.
Drawer Opened
0x10
0x00
0x00
0x0F
Drawer Closed
0x14
0x00
0x00
0x0F