YUNO-II user manual v1.1
27
Open Drawer
Input “
Open Drawer
” command “
1B 70 00 7F 7F
” than
enter, this command will
open drawer.
Read Drawer Status
I
nput “
Read Drawer Status
” command “
1D 72 02
” to read status. The status will
return and display after read command.
Enable ASB
Input “
Enable ASB
“ command “
1D 61 01
”. The drawer will automatic re
port
drawer status when drawer open/close status changed.
Summary of Contents for YUNO II
Page 1: ...YUNO II user manual v1 1...
Page 9: ...YUNO II user manual v1 1 5 2 3 Side View Number Description 11 USB 3 0 Type A...
Page 10: ...YUNO II user manual v1 1 6 2 4 Dimension For YUNO II151...
Page 11: ...YUNO II user manual v1 1 7 For YUNO II156...
Page 28: ...YUNO II user manual v1 1 24...