YUNO-II user manual v1.1
23
Read FW Command
You can send below command sequence to get MCU FW version
Read FW Version
0x1D
0x41
0x30
Y
ou can read FW version after “
Read FW
” command. The FW
version is a ASCII
string.
Open Command
You can send below command sequence to COM port to open drawer.
Drawer 1 Kick Out
0x1B
0x70
0x00
T1
T2
Drawer 2 Kick Out
0x1B
0x70
0x01
T1
T2
T1 / T2 : Drawer kick on time is set to T1 x 2 ms, off time is set to T2 x 2 ms.
The best value for T1/T2 is 7D(125 * 2ms = 250ms)
Note : CDA CD port need to charge power after each time open drawer. The
charge time about 600ms, please wait 600ms at least between two open
drawer command.