NOTE:
If no button is pressed for 10 seconds while changing the configuration
settings, AURATON Libra R will return to the normal operating mode.
PWM operating mode
(Pulse-Width Modulation)
By changing the hysteresis settings (chapter "Configuration settings), we can turn on
the PWM operating mode. In this mode, AURATON Libra R cyclically turns on the
heating device in order to minimize temperature fluctuations. AURATON Libra R
checks the temperature rise times and the temperature drop times.
Knowing these values, AURATON Libra R turns on and off the heating device in
such cycles to keep the temperature as close as possible to the set value.
1 – Temperature
2 – Time
3 – Set temperature
4 – Room temperature