place near the zero crossing of the mains voltage. This prevents the formation of
an electric arc and significantly increases the life of the relay.
The AURATON Fornax receiver is equipped with a unique algorithm for analyzing
the on / off cycles. The entire heating cycle from the last 24 hours is saved in the
receiver's memory. In case of loss of communication with AURATON Libra R
(transmitter), the Fornax receiver will automatically execute the saved cycle of on /
off from the last 24 hours. This gives time to restore the transmission (remove
interferences) or repair the AURATON Libra R without significantly worsening the
thermal comfort in the controlled facility.
Additional remarks
AURATON Libra R (transmitter) must be installed at least 1 meter from the
receiver (too strong a signal from the transmitter may cause interference).
At least 30 seconds must elapse between switching the relay off and on.
Data transmission from AURATON Libra R (transmitter) to the AURATON Fornax
receiver takes place at each change of the ambient temperature by 0.2 ° C. If the
temperature does not change, AURATON Libra R sends control data every 5
minutes (it is manifested by a temporary alternating color change of the LEDs).
In the event of a power failure, the AURATON Fornax receiver will switch off. After
the power is restored, the heating device will be automatically turned on and the
AURATON Fornax receiver will wait for a signal from the paired AURATON Libra
R (transmitter) no later than 5 minutes after the power is restored. After receiving
the signal, the AURATON Fornax receiver will go into normal operation.
Introduction to programming
programming
Manual control
Anti-freeze temperature
Description of AURATON Fornax
Pairing AURATON Libra R of a weekly, wireless
temperature controller (transmitter) with AURATON
Fornax - a wireless controller for a heating or air-
conditioning device (receiver)
RESET AURATON Libra R
MASTER RESET AURATON Libra R
Configuration settings
PWM operating mode
Special situations
Unique features of AURATON Fornax
Additional remarks
Connection diagram of AURATON Fornax
Cleaning and maintenance
Technical data
Disposal of the device
To download
Weekly, wireless temperature controller with
AURATON Fornax heating or air conditioning
controller (set)
The description of AURATON Libra R
The first launch of AURATON Libra R.