Congratulations on purchasing a temperature controller based on 
cutting-edge technological solutions

AURATON 3013

FrostGuard 

function

P

rotects your room against freezing

.

Option to temporarily reduce the programmed 
temperature

 

For maximum 12 hours

Holiday mode

Up  to  eight  days  of  temperature  different  than 
programmed.

Backlit LCD display

Backlit display makes it possible to supervise the device 
operation even in poorly lit rooms

.

3

2

LCD

Description of AURATON 3013 
temperature controller

LCD displa

y

temperature 

setting button

The front panel of the enclosure includes a backlit LCD display, four 
function buttons and temperature setting knob with OK button

temporary temperature 

reduction button

controller 

ON

/

OFF

 button

manual 

mode button

AURATON 3013

knob with 

integrated 

OK button

Summary of Contents for 3013

Page 1: ...Owner s Manual для программного обеспечения вер F0F 3013 www auraton pl AURATON 3013 ...

Page 2: ... FrostGuard function Protects your room against freezing Option to temporarily reduce the programmed temperature Formaximum12hours Holidaymode Up to eight days of temperature different than programmed BacklitLCDdisplay Backlit display makes it possible to supervise the device operationeveninpoorlylitrooms 2 LCD ...

Page 3: ...erature setting button The front panel of the enclosure includes a backlit LCD display four functionbuttonsandtemperaturesettingknobwithOKbutton temporary temperature reduction button controller ON OFF button manual mode button AURATON 3013 knob with integrated OK button ...

Page 4: ...symbol appears when the battery voltage has dropped belowtheacceptablelevel ReplacethebatteryASAP NOTE to maintain the settings the battery replacement should lastlessthan30seconds 3 Temporarytemperaturereductiontime This symbols shows how long the temporary temperature reductionmodewillbeon 4 Display 1 2 3 4 5 6 7 8 9 ...

Page 5: ...s when the mode is not currently on but the function of temporary temperature reduction is active more information in the Setting the temporarytemperaturereductionmode section 7 Controlleronindicator Indicates the device status It appears when the controlled equipmentisturnedon 8 Indicatoroftemporarytemperaturereductionmode Appears when the temporary temperature reduction program isrunning 9 Numbe...

Page 6: ... on the internal wall of the building partition wall in a place with air circulation Avoid installing it in the vicinity of heat generating devices TV set heater fridge or in places exposed to direct sunlight Installing the controllernearadoor mayalsocauseproblemsas thecontrollerwill beexposedtovibrations Selecting a correct location for the AURATON 3013 temperature controller ...

Page 7: ...7 Connecting the leads to AURATON 3013 Toconnecttheleadsremovethefrontpanelasshownbelow The lead terminals are on the controller s back wall under theplasticcover cover screw 1 2 1 2 1 2 ...

Page 8: ...theNCterminalisnotused NOTE Afterconnectingtheleadsreplacetheplasticcover cover Fastening the controller on the wall The battery compartment is located inside the controller in the front part of the enclosure To place the batteries remove the front panel as shown in the section Connecting the leads toAURATON3013 ...

Page 9: ...ing thepolarity TofastentheAURATON3013controllertothewall 1 Remove the controller front panel as shown in the section Connectingtheleadsto3013 2 Drill two 6mm dia holes in the wall set the holes spacing usingthecontrollerrearpanel Placing the front panel NOTE NO COM NC opening for the screw ...

Page 10: ...wall you don t have to use expansion plugs Just drill the 2 7 mm dia holes instead of 6 mm in screw the bolts directly into thewood FRONT PANEL REAR PANEL Placing the front panel NOTE When replacing the front panel onto the rear panel pay attention to thepinconnectionwhichtransmitsthecontrolsignals Pins Pin socket When replacing the front cover make sure that the pins are insertedintothepinsocket ...

Page 11: ...he current temperature in the room will be displayed after a moment The controllerisreadyforoperation Setting the temperature NOTE the first pressing of any function button always turns the display backlighton onlythesecondpressingactivatesagivenfunction Tosettherequiredtemperatureinthenormaloperationmode 1 Pressthe button The temperature display segment will go into the edit mode and will startfl...

Page 12: ...tflashing 2 Turn the knob clockwise or anticlockwise to reduce the temperatureby 1 Cthrough5 C Confirm your choice by pressing the button Press the button and hold below m OK The display will show the moon andthehourcounter 2 Turn the knob clockwise or anticlockwise to set desired temperatureintheroomwiththe0 2 Caccuracy 3 Thecontrollerwillreverttothenormaloperationmode Confirmyourchoicebypressing...

Page 13: ... controller will revert to the basic temperature setting On the display the moon symbol will bereplacedbythesun NOTE The temporary temperature reduction mode always starts when the function is activated This means that the possible temporary temperature reduction should be programmed at the time when you want the temperature change tohappen Switching off the temporary temperature reduction mode Th...

Page 14: ...l show the hand symbol and the tempera ture display segment will go into the edit mode and will start flashing 2 Turn the knob clockwise or anticlockwise to set the desired temperature Confirm your choice by pressing the button 3 The hour field on the display will go into the edit mode and will startflashing Use the knob again to set the number of hours during which themanualmodewillbeon ...

Page 15: ...he manual mode is not automatically repeated When the set time elapses the controller reverts to previous temperature programs normal and temporary temperaturereduction ifthelatterhasbeenprogrammed Switching off the manual mode earlier The controller will run the programmed manual mode until thesettimeelapses Toswitchoffthemanualmodeearlierpressthe buttonagain hand ...

Page 16: ...play will show the symbols Fr and and the relay will activate When the temperature rises to 2 2 C the display willturnoffagainandtherelaywilldisconnectthecontacts FrostGuard function Checking the set temperature By holding the button by minimum 2 seconds you can check thecurrentlyprogrammedtemperature The set temperature display segment will flash after pressing thisbutton Thefunctionisactiveinall...

Page 17: ...ny time by briefly pressingthe button ź Thefirstpressingofanyfunctionbuttonalwaysturnsthedisplay backlight on only the second pressing activates a given function ź During programming failure to press any button for 10 seconds isthesameaspressingthebutton ...

Page 18: ...LCD Maximum load current 16A 250VAC on relay contacts Power supply 2x AAA 1 5V alkaline batteries Disposal The controller bears the WEEE crossed waste bin mark According to the Directive 2002 96 CE and the Waste Electrical and Electronic Equipment Act this marking means that after its life such equipment may not be disposed of together with the householdwaste The user should deliver it to a collec...