PROBLEM CAUSE 

CORRECTION 

Power base not running 

1. Power cord in not connected 
2. Switch in “OFF” position 

1. Connect power cord 
2. Rotate switch to “ON” position 

Fan not running 

1. Power cord in not connected 
2. Switch in “OFF” position 

1. Connect power cord 
2. Pull fan switch 

Unit not misting  

1. Water tank is empty 
2. Misting valve in ”CLOSED” position 
3. Water filter needs replaced 
 

1. Fill tank with DRINKING WATER 
2. Open valve (counterclockwise) 
3. Replace water filter 

Water streaming from nozzle 

1. Air filter needs replaced 
2. Air hose leaks  
 
3. Foreign object in nozzle 

1. Replace air filter 
2. Turn off fan motor, and feel any air 
leaks on hoses 
3. Order and replace nozzle holder 

Water dripping from drain plug 

1. Drain plug not seated 
2.Drain plug seal is missing or 
damage

 

 

1.Properly seat drain plug 
2.Replace drain plug seal

 

 

 
 
 

SAFETY

 WARRANTY

 

WARRANTY 

ONE YEAR FULL WARRANTY 

This product is warranted for one year from the date of purchase against defects in materials and workmanship.  At our 
discretion, parts that prove to be defective will either be repaired or replaced, or the whole product will be replaced.  In 
either case copy of your proof of purchase will be required. 
 
In case that any mechanical or electrical repairs are required during the warranty period send your complete product, 
postage or freight prepaid to the auraMIST service center near you.   Call the number below to get the nearest service 
center.   
 
This warranty does not include the air or water filters, which are expendable parts that can wear out from normal use 
within the warranty period.  This warranty applies for only 90 days if this product is ever used for commercial or rental 
purposes.   
 

AuraMIST, LLC  
5210 Village Parkway 
Rogers, AR 72758 

 
The model number and manufacturing date code can be found on the label attached to the back of the power unit. 
You should record both the model number and the date of purchase and keep in a safe place for future reference. 
 
MODEL NUMBER:   

XXXXX 

MFG DATE CODE:  

XXXX 

SERIAL NUMBER:   

XXXXXXX 

DATE OF PURCHASE: 

XX-XX-XX 

 
CUSTOMER SERVICE NUMBER: 

1-800-320-MIST 

Website: 

   www.auramist.net 

 

Summary of Contents for 1030

Page 1: ...e used in potentially dangerous conditions such as flammable explosive or chemically loaded atmospheres 7 The Misting Fan shall be completely assembled according to these instructions before connecting to power source WARNING DO NOT USE A THREE PRONG TO TWO PRONG ADAPTER IMPROPER CONNECTION MAY CREATE A RISK FOR ELECTRICAL SHOCK 8 The power cord of the Misting Fan is equipped with a three prong gr...

Page 2: ...trical Enclosure Top E 2 2 ST 3 5 x 14 Screw F 2 1 Electrical Enclosure Bottom G 3 2 ST 4 0 x 12 Screw H 4 1 M6 x 24 Screw I 4 1 6 mm Lock Washer J 4 1 M6 Nut K 4 1 M13 X 24 Screw L 4 1 φ13 Pressure Washer M 4 1 M13 Nut N 5 4 M5 Nut O 5 4 φ 5Pressure Washer P 5 4 φ 5Flat Washer Q 6 2 ST 3 0 X 14 R 7 1 Electrical Box Lid S 7 1 Electrical Enclosure T 7 2 ST 3 5 x 10 Screw ...

Page 3: ... Assembly FAN POLE ASSEMBLY TO POWER BASE ASSEMBLY 1 Align fan pole assembly On Off switch to the Ventilation Grill Gently pull hoses from power base assembly A 1 A 1 2 Fasten four places the fan pole assembly to the power base assembly by using fasteners from bag 1 A 2 A 2 3 Fasten electrical housing with 2 screws from bag 2 B 1 Electrical housing 1 2 4 3 5 6 8 On Off switch Ventilation grill 7 H...

Page 4: ... POLE ASSEMBLY TO MOTOR ASSEMBLY 1 Attach the motor to the Center Pole and fasten securely D 1 with all fasteners from bag 4 Use an adjustable wrench to tighten the fasteners FAN GUARD AND BLADE ASSEMBLY 1 Locate the small screw and nut at the bottom of the rear guard and position it so it is pointing to the ground Mount the rear guard to the fan motor with screw from bag 5 E 1 2 Mount the fan bla...

Page 5: ... guard wire E 5 E 5 AIR WATER AND ELECTRICAL CONNECTIONS 1 Connect the air and water tubes to the connectors on the Mist Control Fan Pole Assembly The water is the smaller tube Make sure the tube is pushed all the way into the connector then make the electrical connection F 1 F 1 2 Place the connector inside the electrical housing and then place the housing lid Use screws and the lid from bag 7 to...

Page 6: ...might take around 2 4 minutes for a new misting fan to start misting and it is normal for air to come before water ADJUSTING MIST DENSITY To optimize the cooling effectiveness of the system you can Operate the unit with a DRY or WET mist based on your needs To increase the mist density turn the mist control valve counterclockwise To decrease the mist density turn the mist control valve clockwise W...

Page 7: ...Grill Air Filter Water Filter Ventilation Grill Air Filter Water Filter J 2 The filters are connected to the system via Push In connectors for ease of service Push the connector and pull the hose J 3 Air filter Air filter Water Filter Push In Connector Water Filter Water Filter Push In Connector J 3 Dispose of filter CAUTION IMPROPER PLACEMENT OF THE FILTER CAN DEGRADE SYSTEM PERFORMANCE Remove fi...

Page 8: ... purchase against defects in materials and workmanship At our discretion parts that prove to be defective will either be repaired or replaced or the whole product will be replaced In either case copy of your proof of purchase will be required In case that any mechanical or electrical repairs are required during the warranty period send your complete product postage or freight prepaid to the auraMI...

Reviews: