OPERATING INSTRUCTIONS  

 

Read this owner’s manual before operating this 
product

 

1. To operate the misting fan, plug the power cord into 
a 120 VAC, 60Hz outlet.   
 

CAUTION:

 FAN AND/OR MISTING SYSTEM 

MAY START UP WHEN THE UNIT IS INITIALLY 
PLUGGED TO THE POWER OUTLET. 
 

2. Fan Operation (ON-OFF, Speed control) 
 

Pull Action 

Speed 

First High 
Second Medium 
Third Low 
Fourth “OFF” 

 
3. 

 

Fan Operation (Oscillation Control)  

To turn on the oscillation function, press down the 
oscillation switch, to stop the function simply pull-up 
the oscillation switch. The oscillation angle is 
approximately 50

°

 (G-1) 

 

G-1 

 
4. Misting Operation  

 

IMPORTANT:

 This product is designed to 

operate with DRINKING WATER ONLY.  Fan 
and/or misting system may start up when the unit 
is initially plugged to the power outlet.   
 

BEFORE STARTING

 

• Remove fill cap on power base assembly and fill with 
DRINKING WATER through the basket filter until tank 
is filled to approximately 1” below the bottom of the 
basket filter. 
• Add ½ teaspoon of unscented chlorine bleach to the 
water tank (approximately 5 drops per gallon of drinking 
water). 
• Replace cap and hand tighten.  

  The misting function of this product is turned on by 

simply rotating the switch on the fan pole assembly, 
clockwise.  It might take around 2-4 minutes for a new 
misting fan to start misting, and it is normal for air to 
come before water.  
 

ADJUSTING MIST DENSITY 

To optimize the cooling effectiveness of the system, 
you can: 

 

Operate the unit with a DRY or WET mist, 
based on your needs. 

 

To increase the mist density, turn the mist 
control valve counterclockwise. 

 

To decrease the mist density, turn the mist 
control valve clockwise. 

 

When the misting fan is turned “OFF”, the air-pump 
continues to work for approximately 2 to 4 minutes.  
This allows the air-pump to clear the remaining water 
from the nozzle hoses to prevent accumulation of 
deposits and reduce the risk of clogging. 
 
5. Operating Tips 
Use DRINKING WATER only in the system.  For dry 
climates, increasing the water flow will provide 
maximum cooling results.  In humid climates, a reduced 
water flow is recommended.

 

 
 

MAINTENANCE  

 
WARNING:

 ALLWAYS UNPLUG THE POWER 

CORD BEFORE MOVING OR SERVICING 

WARNING:

 DO NOT IMMERSE THE MISTING 

FAN IN WATER!   

 
CUSTOMER RESPONSIBILITIES 

Read and follow the maintenance schedule and the 
maintenance procedures listed in this section. 
 

EMPTYING WATER TANK 

• 

Place misting fan on surface where water can be 

drained to. 

• 

Remove drain plug by turning counterclockwise. 

• 

Allow tank to drain completely. 

• 

Replace drain plug and hand tighten turning 

clockwise. 
 

CLEANING BASKET FILTER 

• 

Remove fill cap and remove basket filter. 

• 

Rinse debris from filter with running water. 

• 

Replace basket filter and fill cap. 

Summary of Contents for 1030

Page 1: ...e used in potentially dangerous conditions such as flammable explosive or chemically loaded atmospheres 7 The Misting Fan shall be completely assembled according to these instructions before connecting to power source WARNING DO NOT USE A THREE PRONG TO TWO PRONG ADAPTER IMPROPER CONNECTION MAY CREATE A RISK FOR ELECTRICAL SHOCK 8 The power cord of the Misting Fan is equipped with a three prong gr...

Page 2: ...trical Enclosure Top E 2 2 ST 3 5 x 14 Screw F 2 1 Electrical Enclosure Bottom G 3 2 ST 4 0 x 12 Screw H 4 1 M6 x 24 Screw I 4 1 6 mm Lock Washer J 4 1 M6 Nut K 4 1 M13 X 24 Screw L 4 1 φ13 Pressure Washer M 4 1 M13 Nut N 5 4 M5 Nut O 5 4 φ 5Pressure Washer P 5 4 φ 5Flat Washer Q 6 2 ST 3 0 X 14 R 7 1 Electrical Box Lid S 7 1 Electrical Enclosure T 7 2 ST 3 5 x 10 Screw ...

Page 3: ... Assembly FAN POLE ASSEMBLY TO POWER BASE ASSEMBLY 1 Align fan pole assembly On Off switch to the Ventilation Grill Gently pull hoses from power base assembly A 1 A 1 2 Fasten four places the fan pole assembly to the power base assembly by using fasteners from bag 1 A 2 A 2 3 Fasten electrical housing with 2 screws from bag 2 B 1 Electrical housing 1 2 4 3 5 6 8 On Off switch Ventilation grill 7 H...

Page 4: ... POLE ASSEMBLY TO MOTOR ASSEMBLY 1 Attach the motor to the Center Pole and fasten securely D 1 with all fasteners from bag 4 Use an adjustable wrench to tighten the fasteners FAN GUARD AND BLADE ASSEMBLY 1 Locate the small screw and nut at the bottom of the rear guard and position it so it is pointing to the ground Mount the rear guard to the fan motor with screw from bag 5 E 1 2 Mount the fan bla...

Page 5: ... guard wire E 5 E 5 AIR WATER AND ELECTRICAL CONNECTIONS 1 Connect the air and water tubes to the connectors on the Mist Control Fan Pole Assembly The water is the smaller tube Make sure the tube is pushed all the way into the connector then make the electrical connection F 1 F 1 2 Place the connector inside the electrical housing and then place the housing lid Use screws and the lid from bag 7 to...

Page 6: ...might take around 2 4 minutes for a new misting fan to start misting and it is normal for air to come before water ADJUSTING MIST DENSITY To optimize the cooling effectiveness of the system you can Operate the unit with a DRY or WET mist based on your needs To increase the mist density turn the mist control valve counterclockwise To decrease the mist density turn the mist control valve clockwise W...

Page 7: ...Grill Air Filter Water Filter Ventilation Grill Air Filter Water Filter J 2 The filters are connected to the system via Push In connectors for ease of service Push the connector and pull the hose J 3 Air filter Air filter Water Filter Push In Connector Water Filter Water Filter Push In Connector J 3 Dispose of filter CAUTION IMPROPER PLACEMENT OF THE FILTER CAN DEGRADE SYSTEM PERFORMANCE Remove fi...

Page 8: ... purchase against defects in materials and workmanship At our discretion parts that prove to be defective will either be repaired or replaced or the whole product will be replaced In either case copy of your proof of purchase will be required In case that any mechanical or electrical repairs are required during the warranty period send your complete product postage or freight prepaid to the auraMI...

Reviews: